Technical Data - Rangemaster Professional 90 Gas FSD User Manual

Table of Contents

Advertisement

Technical Data

This cooker is designed for use on either :-
NATURAL GAS (Cat I2H ) at 20mbar or
LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND
CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp
/
at rear right-hand side
1
2
Ratings
Hotplate
Wok burner
Large Burner
Medium Burners
Small Burner
Main Oven
Grill
Gas burner inputs based on Gross Calorific Value
Tall Oven
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
Maximum total electrical load at 230V 2.6kW (approximate total including oven light, oven fan etc.)
Electric
20mbar
220 - 240V 50Hz
29mbar
37mbar
Overall height
Overall width
Overall depth
Space for fixing
Electric
Natural Gas
3.5kW
external 129
3.0kW
1.7kW
1.0kW
3.2kW
2.73kW
Energy consumption based on standard load
minimum 893mm
900mm See 'Positioning of Cooker'
648mm
See 'Positioning of Cooker'
650mm
220 - 240V 50Hz
L.P. Gas
Injector
internal 80
3.5kW (246g/h)
134
3.0kW (210g/h)
109
1.7kW (119g/h)
75
1.0kW (70g/h)
237
2.9kW (224g/h)
190
2.73kW (192g/h)
Usable volume (litres)
Time to cook standard load
Surface area of the grid
36
maximum 920mm
Injector
internal 54
external 77
87
68
51
85
85
Forced air convection
2.5kW
B
0.95kWh
53
Size
Medium
49 minutes
790cm
2