Local Mode Programming Instructions - Ultimate Technology 500 POS User Manual

Pos keyboard
Table of Contents

Advertisement

To program the Series 500 Keyboard in the local mode proceed as follows:
1. Swipe the Programmer's card supplied with the keyboard in the magnetic stripe reader
(MSR).
For Series 500 Keyboards equipped with the optional 3-position keyswitch
adjacent to the LED indicators, set the switch to the AUX position and enter 882 on the
keyboard numeric keypad.
2. All LED indicators turn on and the keyboard enunciator beeps three times.
3. After step 2 is complete, LED indicator (1) will flash continuously to indicate that the
keyboard programming mode is active.
4. For a summary of the parameters that can be programmed in the local mode, refer to Table
2 preceding.
5. Follow the instructions given in Table 3 for the applicable Function Code(s) to program the
keyboard for the desired parameter(s). Note that sequence of instructions provided in
Table 3 is in Function Code numerical order.
6. When programming is complete, exit the local programming mode by typing 99 on the
Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position. This returns the
keyboard to normal operation.

LOCAL MODE PROGRAMMING INSTRUCTIONS

Some programming options may not be
activated until the keyboard is re-powered.
Serial port communication selections --
Function Codes 10-24; 30-34; 91;
NOTE
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

500 series

Table of Contents