Table 3. Local Mode Programming Instructions - Continued
Function Code(s)
90
Dump System Log
91
Main Port Select
96
Set Secure Mode
Note: *Default Settings
Operation
Normal Indication
on Series 500 Keyboard numeric keypad or by swiping the Programmer's
card. If using the optional 3-position keyswitch, move switch out of the
AUX position.
This is a command used to read out the Series 500 Keyboard system log data at the
main port. For detailed information about retrieving the system log data, refer to the
Maintenance Section of this manual.
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 91.
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to
select LED mode of operation per list below.
0 = Keyboard Port 0 is main
1 = RS232 Port 0 is main
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
Note: Must re-power Series 500 Keyboard in order to activate function code.
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 96
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to
select override secure mode of operation per list below.
0 = not secure
1 = secure
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.