Table 5. Remote Programming Mode Commands - Continued
OP
MNEMONIC/DESCRIPTION
CODE
(HEX)
B2
Sends data to selected port: main
serial port, auxiliary serial port, or
auxiliary keyboard port.
B3
Sends all error information to main
port for output.
SENDP
RDERROR
COMMAND/ACKNOWLEDGEMENT
COMMAND: B2p...........<CR>
B2
= Op Code
p
= data destination port
<CR> = terminate command (0D hex)
p:
0 = serial port 0 (main)
1 = serial port 1 (auxiliary)
2 = keyboard port 0 (main)
3 = keyboard port 1 (auxiliary)
4 = cash drawer 1 fire
5 = cash drawer 2 fire
Where data can be ASCII or CxDx (high and
low nibble hex value) type.
ACKNOWLEDGEMENT: NONE
COMMAND: B3<CR>
B3
= Op Code
<CR> = terminate command (0D hex)
Sends all error log information contained in
the non-volatile memory (NVRAM) out the
main port.
ACKNOWLEDGEMENT: NONE