Table 3. Local Mode Programming Instructions - Continued
Function Code(s)
45
46
47
48
Drawer 1
Open (45)
Closed (46)
Drawer 2
Open (47)
Closed (48)
49
Poll/
Unsolicited
Cash Drawer Status
Note: *Default Settings
Operation
Normal Indication
1. While in programming mode, at the Series 500 Keyboard numeric keypad, enter
applicable Function Code 45, 46, 47 or 48.
LED (2) flashes.
2. At the auxiliary keyboard, press the desired key or type the desired key sequence.
Note that the maximum number of key codes is limited to 24 - this is equivalent to
approximately 12 key strokes.
3. At the Series 500 Keyboard, press ENTER.
LED (2) turns off.
4. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 49.
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1 ) to
select status method per list below.
0 = Send on change or transition
1 = Send only with poll command CDSTATUS
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
Remarks
If the Series 500 Keyboard beeps and
LED (2) turns off while entering key
codes at the auxiliary keyboard, you
have exceeded 24 key codes. Repeat
steps 1 and 2.