Ultimate Technology 500 POS User Manual page 55

Pos keyboard
Table of Contents

Advertisement

Table 5. Remote Programming Mode Commands - Continued
OP
MNEMONIC/DESCRIPTION
CODE
(HEX)
B4
Writes programming changes to
the NVRAM. Always apply the
COMMIT command after
programming the keyboard to save
the changes in the NVRAM. Failure
to use the COMMIT command will
result in the loss of the changes the
first time power is removed from
the keyboard.
B5
Resets keyboard after downloading
configuration. On receipt of this
command the unit does a warm
boot.
B6
Used to select when keyswitch 1, 2
or 3 MAKE/BREAK codes are
sent. Two options are available:
unsolicited mode where codes are
sent whenever the keyswitch is
rotated, or solicited mode where
codes are sent only when a OP
Code B7 command is received.
B7
Send keyswitch MAKE/BREAK
codes in current keyswitch 1, 2 or 3
position.
COMMIT
RESET
KSSND
KSSTATUS
COMMAND/ACKNOWLEDGEMENT
COMMAND: B4<CR>
B4
= Op Code
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
COMMAND: B5RST<CR>
B5
= Op Code
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
COMMAND: B6<CR>
B6
= Op Code
x
A = unsolicited
B = solicited
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
COMMAND: B7<CR>
B7
= Op Code
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
47

Advertisement

Table of Contents
loading

Related Products for Ultimate Technology 500 POS

This manual is also suitable for:

500 series

Table of Contents