Table 5. Remote Programming Mode Commands - Continued
OP
MNEMONIC/DESCRIPTION
CODE
(HEX)
B8
Use to send magnetic card reader
track data for any one good track or
if both tracks are good.
B9
Enables or disables tracks on
magnetic card reader.
MSRSND
CARDED
COMMAND/ACKNOWLEDGEMENT
COMMAND: B8x<CR>
B8
= Op Code
x
A = send any good track
B = send if both tracks are good
<CR> = terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
COMMAND: B9c<CR>
B9
= Op Code
c
= track selection
<CR> = terminate command (0D hex)
Track selection:
A
= track 1 on
B
= track 2 on
C
= track 3 on
D
= track 1 and 2 on
E
= track 2 and 3 on
F
= all tracks off
ACKNOWLEDGEMENT: NONE