Table 3. Local Mode Programming Instructions - Continued
Function Code(s)
02
Copy Primary Key
Functions to
Secondary Key
Positions
08
Enable /Disable
Magnetic Stripe
Reader (MSR)
Tracks
Note: *Default Settings
Operation
Normal Indication
p o s i t i o n k e y s w i t c h , m o v e s w i t c h o u t o f t h e A U X p o s i t i o n .
1. While in programming mode, at the Series 500 Keyboard numeric
keypad, enter Function Code 02.
LED (2) turns on.
2. At the Series 500 Keyboard, press the designated key to copy its
primary function into the secondary position.
3. Repeat 2 for next key to be programmed
4. When completed, press ENTER.
LED (2) turns off.
5. Program the next function code or exit programming mode by entering 99
on Series 500 Keyboard numeric keypad or by swiping the Programmer's
card. If using the optional 3-position keyswitch, move switch out of the
AUX position.
Note: A Sec Op Key or Sec Op Lock Key must be programmed in the
primary function mode in order to use secondary function codes.
1. While in programming mode, at the Series 500 Keyboard numeric
keypad, enter Function code 08.
LED (2) turns on.
2. At the Series 500 Keyboard numeric keypad, enter the applicable
number (1 through 6) to select the MSR track configuration per list
below.
LED (2) turns off.
3. Program the nex t function code or exit the local programming mode by
entering 99 on Series 500 Keyboard numeric keypad or by swiping the
Programmer's card.
switch out of the AUX position.
1 = Channel 1 enabled
2 = Channel 2 enabled
3 = Channel 3 enabled
4 = Channels 1 and 2 enabled*
5 = Channels 2 and 3 enabled
6 = All channels disabled
If using the optional 3 -position keyswitch, move