Table 3. Local Mode Programming Instructions - Continued
Function Code(s)
21 or 31
Main Port 0 (21)
AUX Port 1 (31)
Stop Bits
22 or 32
Main Port 0 (22)
AUX Port 1 (32)
Parity
Note: *Default Settings
Operation
Normal Indication
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 21 (Port 0) or 31 (Port 1).
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the number of stop bits (1 or 2) per
list below.
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 22 (Port 0) or 32 (Port 1).
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0, 1 or 2) to
select type of parity per list below.
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
1 = one stop bit
2 = two stop bits*
0 = none*
1 = odd
2 = even
24
Remarks