Assembly Instructions; For The Installer And Kitchen Expert; Important Installation Notes - Siemens HB 56 M 550 Operating And Fitting Instructions Manual

Hide thumbs Also See for HB 56 M 550:
Table of Contents

Advertisement

Available languages

Available languages

Assembly Instructions

For the installer
and kitchen expert!
Important installation
notes
The connection diagramm is
located on the rear panel of the
appliance.
1
~
220-230V
L1
1
~
380-400V2N
L1
1
~
380-400V3N
L1
128
Properly dispose of packaging materials.
Do not use oven door handle for
transporting or handling the unit during
installation.
WARNING: Connection and first start of the
appliance may only be performed by an
authorised specialist.
Connection must be made using an
H 0 5 R R - F 3 G 1,5 mains connection cable.
Rated consumption, rated voltage and type
no. of the appliance:
See appliance nameplate behind the oven door
to the left beneath the side edge of the oven.
The unit's nameplate is located at on the
sidewall of the unit.
Electrical safety of the appliance can be ensured
only if the equipment earth in the building
installation has been installed according to
regulations.
A separator must be installed in the household
circuit. A suitable separator is a switch that has a
contact gap of more than 3 mm and interrupts all
poles. Other examples are LS switches, fuses
and contactors.
In the case of repairs interrupt all power
2
3
4
5
connections to the unit.
N
2
3
4
5
The properly installed appliance must be covered
L3
N
on all sides in such a fashion that not even
2
3
4
5
L2
L3
N
components with rough insulation are exposed to
the touch.
The cover must be removable with tools only.