Micro Switch (Option) - KEB COMBISTOP 38 Instruction Manual

Electromagnetically actuated dual-surface spring-applied brake for dry running
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Mounting and Start-up
Screw the handle (2) onto the hand release bracket (1).
Depending on the design and size of the brake (see table), slide the screws along
with the discs and springs (3) to (10) through the provided holes in the magnet,
armature disc and hand release bracket (1) as shown in the drawing.
Use the disc (6 or 7) to secure the hand release bracket, then tighten it using self-
locking hexagon nuts (8).
Warning!
Checking the Adjustment Dimension 'm'
The adjustment dimension 'm' must be adjusted with attracted armature!
Caution!
4.1.4

Micro Switch (Option)

A micro switch can be used to monitor the switching state of the armature (brake
open/closed). The user is responsible to connect the electrical equipment and to
evaluate the signals! The drive control must not allow the motor to start until the
armature was attracted by the magnet, i. e., the lining can rotate freely.
The micro switch is factory-mounted to the brake as well as factory-set and secured.
Warning!
In the event of any malfunction affecting the switching function, check the micro switch
settings and, if necessary, replace the micro switch (see sections below).
01.09.2011 Rev. 01
Loss of Braking Efficiency!
For the safe operation of the brake, the correct adjustment / inspection
of the adjustment dimension 'm' is mandatory!
Improper adjustment and operation with overexcitation may result in
loss of braking efficiency!
Note!
The adjustment dimension 'm' (see table on page 15) applies to rated
torque and operation with rated voltage. In case of different operating
conditions, please consult the manufacturer.
Brake Malfunction!
Changing the settings of the micro switch may cause drive / brake
malfunctions.
COMBISTOP Type 38
Page 17

Advertisement

Table of Contents
loading