Mounting and Start-up
Size
Design
Nominal air gap
X
[mm]
For more information on how to check the air gap which becomes larger as a result of
wear and how to readjust the air gap, refer to section "7.3 Maintenance Work".
4.1.3

Mounting the Hand Release (Option)

This section describes the subsequent mounting of the optional hand release to the
brake.
01.09.2011 Rev. 01
02
03
04
N/H
N/H
N/H
0.2
0.2
0.2
Note!
The type of hand release attachment to the brake may vary depending
on the ordered design (N/H) and size of the brake.
For information on the components (items 1 to 10) to be used for
installation, refer to the exploded assembly drawing and the table on
the next page.
COMBISTOP Type 38
Checking the Air Gap X
Use a feeler gauge (F) to check the air
gap X as described in section "7.3.1
Checking the Air Gap". If the air gap X
is larger than X
n
readjusted. To this end, follow the
instructions in section "7.3.2
Readjusting the Air Gap".
05
06
07
N/H
N/H
N/H
N/H
0.2
0.3
0.3
0.4
, the air gap must be
08
09
10
11
N/H
N/H
N/H
0.4
0.5
0.6
Page 14