Checking The Micro Switch Settings - KEB COMBISTOP 38 Instruction Manual

Electromagnetically actuated dual-surface spring-applied brake for dry running
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Mounting and Start-up
Connecting the Micro Switch
Connect the micro switch as a normally open contact (terminal 1 and 4).
After installation, check the switching point of the micro switch. If necessary,
readjust the micro switch (to this end, refer to the next sections).
4.1.4.2

Checking the Micro Switch Settings

Warning!
By repeatedly switching the brake, check the two switching states:
Brake energised: ON signal (micro switch closed)
Brake de-energised: OFF signal (micro switch open)
01.09.2011 Rev. 01
Loss of Braking Efficiency!
Before checking the micro switch settings, mechanically secure the
load against unintended movements and disconnect the brake from
load!
COMBISTOP Type 38
Strands for the Micro Switch
1 = ground (black)
2 = normally closed contact (brown)
4 = normally open contact (red)
Page 19

Advertisement

Table of Contents
loading

Table of Contents