Oex Switch Wiring Diagrams; Figure 27 Oex Wiring Ac Side Switching - Independent Contactor Switching - Phase To Phase - KEB COMBISTOP 38 Instruction Manual

Load brake size 9
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Rectifiers

7.1.3 OEX Switch Wiring Diagrams

The OEX Rectifier excites the brake magnet with the nominal voltage and then reduces
the voltage by 50% for holding. This reduced holding voltage significantly reduces the
power consumption and speeds up the engagement of the brake when the voltage is
switched off.
AC Side – Independent Contactor Switching – Phase to Phase
Switching: AC Side
Line Voltage: 208VAC
Line Voltage: 230VAC
F
= Class CC fuse max. 5A
brk

Figure 27 OEX Wiring AC Side Switching - Independent Contactor Switching - Phase to Phase

42
Figure 4.2.4
Rectifier: OEX Switch
Input Voltage: 208VAC
Input Voltage: 230VAC
Independent Contactor rated 300VAC, min 5A AC1
Model Number: 9098200-CE09
Coil Voltage: 170VDC
Coil Voltage: 205VDC
2021 KEB America, Inc.
©