Rectifiers
7.2.2

230VAC OEX Switch Wiring Diagrams

Full Wave > Half Wave Rectification
230VAC Full Wave (205VDC) for 0.35s then 230VAC Half Wave (105VDC) holding
voltage
Specifcation
Rated Input Voltage
Full Wave UL Current
Half Wave UL Current
Max Operating Temperature
Terminal Wire Size
NOTICE
2020 KEB America, Inc.
©

Figure 26 Example OEX Switch 230VAC Wiring Diagrams

Required Rectifier Specifications
 Contactors must have a minimum AC-1 rating of 24A or a minimum
AC-3 rating of 9A. An optional MOV may be used for DC coil and
contactor protection for coil voltages ≥ 180VDC.
i
 These diagrams are wiring suggestions. Other wiring solutions are
possible. Please contact KEB America, Inc. for any questions.
Value
180-300 VAC 50/60 Hz ± 10%
2.4A
1.2 A
75°C
1.5mm / AWG 15