Mounting and Start-up
4.1.5.1

Connecting the Brake

Caution!
To connect the brake to an AC voltage source, a rectifier needs to be installed
upstream of the brake. For more information in rectifiers, refer to the separate
COMBITRON rectifier manuals.
AC Side Switching
Prior to start-up, attach the jumper according to the following figures [1] to [2].
Risk of Damage to the Brake!
For frequency converter operation, the wiring according to figure [2] and [3] is not
allowed.
For cables longer than 10 m between rectifier and brake, an appropriate switch is
Caution!
mandatory (figure [1]).
The voltage supply must not be picked off downstream of the motor contactor
(figure [2]).
01.09.2011 Rev. 01
Risk of Damage to the Brake!
The maximum input voltage U
The magnet coil must be connected to a DC voltage source.
COMBISTOP Type 38
must not be exceeded.
in
Page 22