Continued from the previous page.
3. Open valve (4).
4. Position the HEAT XCHANGER within the space to be heated.
5. Connect the HEAT XCHANGER supply hose (a) to the HTF supply line (b).
6. Connect the HEAT XCHANGER HTF return hose (c) to the accessory HTF
return port (d).
7. Insulate the supply and return hoses.
8. Close the Pump Pack HTF supply valves (f).
9. Connect the HEAT XCHANGER to the appropriate electrical source.
NOTICE: Only turn on the pumps when the HEAT XCHANGER is connected.
Turning on the pumps when the HEAT XCHANGER is not connected will cause
excess system pressure which will damage the pumps.
10.Start the parent machine. Operate the parent machine with the temperature
controller set to 80°C.
11.Turn on the HEAT XCHANGER and adjust its thermostat as desired.
Result
The HEAT XCHANGER has now been connected and is operating.
wc_tx001668gb.fm
4
HX 60
HX 200
67
Accessories
wc_gr007814