SM Split CS Series Heat Pump
TXV Adjustments for SM Split CS when Paired with BOSCH BMAC
BMAC2430BNTD
CS MODEL
None
SM024-1CSC
None
SM024-1CSN
SM036-1CSC
SM036-1CSN
SM048-1CSC
SM048-1CSN
SM060-1CSC
SM060-1CSN
Table 7 TXV Adjustments for SM Split CS when Paired with BOSCH BMAC
BVA2.0 Rated Airflow Adjustment when Paired with SM Split CS Models
CS Model
SM024-1CS
SM036-1CS
SM048-1CS
SM060-1CS
Table 8 BVA2.0 Rated Airflow Adjustment when Paired with SM Split CS Models
SM Split CS Series Heat Pump
Cased/Uncased Coil Model
BMAC3036BNTD
SM: 1 Turn Closed
BMAC: None
SM: 1 None
BMAC: None
Air Handler
Full-Load-Rated
BVA24
BVA36
BVA48
BVA60
Subject to change without prior notice
BMAC4248CNTF
SM: 1 Turn Closed
BMAC: None
SM: 1 Turn Closed
BMAC: None
Part-Load-Rated
Airflow
Airflow
900
1200
1600
1200
1700
1400
Refrigerant Lines | 13
BMAC4860CNTF
SM: None
BMAC: 1 Turn Closed
SM: None
BMAC: 1 Turn Closed
Blower Setting
(High/Low)
600
5/3
900
5/3
4/2
5/3
8733825873 (2020/05)