SM Split CS Series Heat Pump
Liquid Line Charge per Linear Foot
LIQUID LINE
SIZE, O.D.
R410A OZ
PER FOOT
Table 3 Liquid Line Charge per Linear Foot
Additional Adjustments Required when Pairing SM Split CS with BVA2.0 and BMAC
1. Adjust factory charge as per Table #4 or Table
#5 as appropriate, and then proceed with
additional charge adjustment calculations by
line size as per Table #2.
2. Adjust TXV as per Table #6 or Table #7, as
Charge Adjustments (oz) for SM Split CS when Paired with BOSCH BVA2.0
BVA-24WN1-M20
CS MODEL
SM024-1CSC
SM024-1CSN
SM036-1CSC
SM036-1CSN
SM048-1CSC
SM048-1CSN
SM060-1CSC
SM060-1CSN
Table 4 Charge Adjustments (oz) for SM Split CS when Paired with BOSCH BVA2.0
SM Split CS Series Heat Pump
1/4
5/16
.25
.44
BVA-36WN1-M20
-6
-9
Subject to change without prior notice
3/8
.60
appropriate.
3. Adjust BVA motor setting as per Table #8 to
obtain the rated airflow. Refer to the BVA2.0
operational manual for additional airflow
settings.
Air Handler Model
BVA-48WN1-M20
0
0
Refrigerant Lines | 11
1/2
5/8
1.15
1.95
BVA-60WN1-M20
13
8
0
0
8733825873 (2020/05)