Dräger Fabius CE Instructions For Use Manual page 13

Auxiliary fresh-gas outlet
Hide thumbs Also See for Fabius CE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Using the external fresh gas outlet as a common gas outlet (optional)
The external fresh gas outlet is the interface for
various non-rebreathing systems.
Overview
6
5
4
1 External fresh gas outlet
2 Long fresh gas hose (to Fabius)
3 Short fresh gas hose (on the compact breathing
system, COSY)
4 Compact breathing system, COSY
5 Sample line
6 Non-rebreathing system (e.g. Bain)
1
2
3
Supplement to Instructions for Use
Preparation
Example: Bain non-rebreathing system
3
3
1 Disconnect the short fresh gas hose from the
external fresh gas outlet.
2 Connect the non-rebreathing system to the
external fresh gas outlet.
3 Screw the sample line to the connections on the
breathing mask or the breathing system filter
and to the water trap on the gas monitor.
4
4 If required, connect the anesthetic gas
scavenging hose of the non-rebreathing system
to the second port of the anesthetic gas
receiving system (AGS).
2
1
13