Maintenance and Repair

8
Maintenance and Repair
8.1

Maintenance

The sensor's transmission properties are stable over long periods. For this reason, regular
adjustments to, and maintenance on the sensor itself, are not necessary. Nevertheless check in
the course of normal maintenance intervals that the sensor, the actuator and the connector are
securely attached. Also check that the connecting cable is intact and correctly routed.
8.2

Resetting the output functions to default

The resetting process is initiated using the button on the sensor.
Default setting PMI360DV-F130-IU-V15
Reset process
1.
Press and hold the sensor button.
The associated yellow LED starts to flash slowly after 2 seconds.
2.
Continue to hold the sensor button.
The LED begins to flash more quickly after an additional 10 seconds.
3.
Then release the button within 3 seconds.
The output is reset to default, now.
Note
If the button is pressed and held for more than 15 seconds, the associated LED starts to flash
slowly again. The "Power/Error" LED then flashes red at the same time. This fault signal
indicates that the button is stuck. A reset to default does not occur in this case. As soon as the
button is released, the "Power/Error" LED stops flashing red and lights up green permanently.