5.1.3

Workpiece lead, general

Risk of burning due to incorrect welding current connection!
If the welding current plugs (machine connections) are not locked or if the workpiece
connection is contaminated (paint, corrosion), these connections and leads can heat up
and cause burns when touched!
Check welding current connections on a daily basis and lock by turning to the right when
necessary.
Clean workpiece connection thoroughly and secure properly. Do not use structural parts of
the workpiece as welding current return lead!
5.1.4

Transport belt

5.1.4.1

Adjusting the length of the carrying strap

To demonstrate adjustment, lengthening the strap is shown in the figure. To shorten, the strap's
loops must be inched in the opposite direction.