Welding Data Display - EWM Pico 350 cel puls Operating Instructions Manual

Hide thumbs Also See for Pico 350 cel puls:
Table of Contents

Advertisement

Item Symbol
8
9
10
4.2.1

Welding data display

All relevant welding parameters with their values are shown depending on the welding procedure selected
and the associated functions. Machine parameters and error codes are shown as well in a unique man-
ner. The meaning of the parameters and values shown is explained in the relevant chapter for the func-
tion.
Next to the display is the Display/Power-saving mode switching push-button. Each time the push-button is
pressed the display switches between the desired parameters.
Depending on the process, the parameters are shown as nominal values (before welding), actual values
(during welding) or hold values (after welding):
MMA welding, TIG welding and MIG/MAG welding with constant current (CC):
Welding current (AMP)
Welding voltage (VOLT)
Welding performance (kW)
Open circuit voltage
By turning the rotary transducer for the welding parameter settings the display automatically switches to
the welding current display.
MIG/MAG welding with constant voltage (CV):
Welding current (AMP)
Welding voltage (VOLT)
Welding performance (kW)
By turning the rotary transducer for the welding parameter settings the display automatically switches to
the welding voltage display.
optionally adjustable – > see 5.9 chapter
[*]
099-002060-EW501
30.04.2020
Machine description – quick overview
Description
0
Welding procedure/MMA characteristics selection push-button
Select MMA welding procedure and electrode type
R ---------- Rutile electrode type
RB / RC - Rutile-basic/rutile-cellulose electrode type
B ---------- Basic electrode type
C ---------- Cellulose electrode type
Display/Power-saving mode switching push-button
AMP ----- Welding current display
VOLT ---- Welding voltage display
kW-------- Welding performance display (both signal lights are illuminated)
STBY ---- Press for 2 s to put machine into power-saving mode. To reactivate, activate
one of the operating elements.
Welding data display (3-digit)
Displays the welding parameters and the corresponding values > see 4.2.1 chapter
Nominal values
Nominal values
Machine control – Operating elements
Actual values
/
Actual values
Hold values (5 s)
[*]
[*]
/
Hold values (5 s)