Validity; Proper Use; Air Cooling Units, 24 V Dc - Pfeiffer Vacuum HiPace Series Operating Instructions Manual

Air cooling unit
Table of Contents

Advertisement

1

Validity

2

Proper use

3

Air cooling units, 24 V DC

3.1
HiPace 30
This operating manual is for customers of Pfeiffer Vacuum. It describes the functioning
of the designated product and provides the most important information for safe use of
the unit. The description follows applicable EU guidelines. All information provided in this
operating manual refers to the current state of the product's development. The documen-
tation remains valid as long as the customer does not make any changes to the product.
Up-to-date operating instructions can also be downloaded from
www.pfeiffer-vacuum.com.
● The air cooling serves to the cooling of Pfeiffer Vacuum turbopumps at ambient tem-
peratures of max. + 35 °C.
● Type selection according to the accessories recommendation of the respective tur-
bopump.
Improper use will cause all claims for liability and warranties to be forfeited. Improper use
is defined as usage for purposes deviating from those mentioned above, especially:
● connection to pumps or units which are not suitable for this purpose according to their
operating instructions
● connection to units which have exposed voltage-carrying parts
Standard:
Shielded variants
Power consumption
Control voltage
Electric connection
Fig. 1:
Connecting the air cooling
3
Pump lower part
3a
Air cooling unit
 Fix the air cooling unit to the holes of the turbopump using two screws.
 Plug in and fix the accessory's control lead to a free connection port on the connecting
cable or adapter of the electronic drive unit.
PM Z01 300 A
PM Z01 301 A
PM Z01 348 A
PM Z01 361 A
PM Z01 360 A
1.32 W
3.84 W
24 V DC
24 V DC
M8
M8
3
3b
Hexagon screw
PM Z01 302 A
PM Z01 303 A
PM Z01 362 A
PM Z01 363 A
3.84 W
3.84 W
24 V DC
24 V DC
M12
M12
3a
3b