Dimensions:
Model
Width
Width not
including
including
Switchboard
Switchboard
( mm )
( mm ) )
940
FTG 120
820
940
FTG 150
820
980
FTG 240
860
980
FTG 300
860
ELECTRIC SUPPLY
Voltage of the oven: check whether voltage of the equipment is the same of your
electric supply.
Wall socket: socket where oven is to be connected should be a monophase or 3-phase
fix plug, dimensioned for the nomina l current of the protection circuit ( thermal-electrical
breaker), allowing full exemption of plug pins, without any clearances, so that sharp live parts
cannot be touched by human hand.
Socket wiring: they should be rigorously in accordance with their respective compensations
as described in the Brazilian Standard NBR 5410 - ABNT ( Associação Brasileira de Normas
Técnicas - the Brazilian Association for Technical Standards ). Should you have any doubts
consult a specialized electrician.
Protection: : at the circuit where oven is to be plugged to, there must be a thermal-electrical
circuit breaker as per the table below.
Model
Voltage
Mono 110V
FTG 120
FTG 150
Mono 220V
FTG 240
Mono 110V
FTG 300
Mono 220V
Ground wiring or Earth wire: ground wire of your oven should be connected to an effective
earth cable, thus preventing from personal risks. Connection to a ground wire is necessary
under any voltage, and should not be connected to the neutral wire of the power supply, neither
to the hydraulic, gas or electrical piping, nor the faucets, etc. For a perfect ground wiring,
observe instructions under the Brazilian Standard NBR 5410 - ABNT, "Grounding Wire".
It is the customer's responsibility if it is not possible to turn equipment on.
A CONNECTION TO A GROUND WIRING SYSTEM IS MANDATORY.
Electrical extension cords or the like: for no reason whatsoever should you connect any
other equipment to the same wall socket. That can cause an overload on the electrical supply
and/or bad contact. Overloads can cause prejudicial heating to insulation of the connections,
the terminals or surroundings of the conductors, and cause damages and it may even burn the
installations or the product.
Width
Width not
including
including
Base
Base
( mm )
( mm )
1530
580
1610
660
1700
1160
1770
1000
Motor Power
Protection Circuit
Breaker Recommended
1/4 Hp
15A
1/4 Hp
15A
1 Hp
15A
1 Hp
15A
18
Depth
( mm )
GROUNDING WIRE: Installing ground wiring is mandatory for safety matters whatever
voltage of the product. Be careful! Ground wiring should not be connected to neutral wire
of the power supply. neither to water nor gas pipes, etc.
1300
1300
1470
1470
5) ASSEMBLING THE SUPPORTING RACK
This supporting rack is supplied disassembled
only for models FTG 120 - FTG 150.
In order to assemble it correctly, follow steps
shown in the drawing below:
HOW TO PUT YOUR EQUIPMENT INTO OPERATION
After observing recommendations described previously as for proper functioning of the
equipment, it will be ready to be used.
1) Lamp Switch Key
2) Timer Start Switch Key
3) Decrease Switch Key ( - )
4) (PGM) Programming
5) Increase Switch Key (+)
6) Steam Switch Key
7) Time Display
8) Temperature Display
9) Flame Indicator
10) Indicator for Time Decreasing
GAS TURBO OVEN
FTG 300-240-150-120
ATTENTION
8
7
On / Off Switch key
Emergency Switch Key
23
6
5
4
3
2
1
10
9