Operation
Example 90% Efficiency
Condensing Furnace
Condensing
furnaces/
boilers can be tested
through a hole drilled in
the
plastic
vent
pipe
(when allowed by the
manufacturer
or
local
authority of jurisdiction)
or taken from the exhaust
termination.
IMPORTANT:
combustion device being tested, and be aware of accepted
practices of the local jurisdiction before introducing sampling holes
into exhaust pipes or ducts.
CAUTION: To avoid the introduction of dangerous exhaust gases
into the space, be sure to completely and securely seal any sampling
holes made in the exhaust pipes or ducts.
42
www.
Fyrite
Example 80% Efficiency
Fan Assist or Power
Vented Furnace
Combustion testing of fan
Boilers, which have a 'bell'
assist or power vented,
shaped draft diverter on
furnaces/boilers should be
top, should be tested
done
through
a
hole
directly below the diverter
drilled
in
the
vent
through a hole drilled in
immediately above the
the vent connector.
inducer fan.
Review manufacturer recommendations for the
.com
InTech
Manual
Example
Atmospheric/Gravity
Vented Boiler
0024-9486 Rev 4