1. Overview

Thank you for investing in the Bacharach CO Appliance Kit. The kit is to be used in
conjunction with the Fyrite
combustion analyzer, and the Monoxor
Figure 1. Bacharach Analyzers with CO Appliance Kit
The kit consists of two interchangeable probes and a tubing assembly. The special
probes included in the kit are used in place of the probe assembly that is supplied with
your Bacharach combustion analyzer, and are designed to standardize the measurement
process and normalize readings of CO gas from common appliances when adhering to
European standard EN7967.
IMPORTANT: The CO Appliance Kit is to be used only with the Bacharach
Monoxor® Plus CO analyzer and Bacharach combustion analyzers configured
to use Siegert combustion equations. Refer to your instrument's instruction
manual for complete operation instructions.

2. Safety

Be sure to read, understand, and follow all safety warnings listed below and included
with your combustion analyzer.
WARNING: The Bacharach combustion analyzer is not intended to be used as
a safety device.
0024-9498 Rev 0
GlobalTestSupply
www.
CO Appliance Kit
Fyrite
INSIGHT
Plus Combustion Analyzer
Fyrite
InTech
Combustion Analyzer
Monoxor
Plus Carbon Monoxide Analyzer
INSIGHT
Plus combustion analyzer, Fyrite
Plus carbon monoxide analyzer.
for use with:
InTech
1
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0024-8555 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bacharach 0024-8555

  • Page 1 InTech Combustion Analyzer October 2014  Monoxor Plus Carbon Monoxide Analyzer 1. Overview Thank you for investing in the Bacharach CO Appliance Kit. The kit is to be used in     conjunction with the Fyrite INSIGHT Plus combustion analyzer, Fyrite InTech ...
  • Page 2 When testing an appliance, a full visual inspection of the appliance should be performed to ensure its safe operation. CAUTION: The Bacharach analyzer is not intended to be used on a continuous basis. CAUTION: Do not store instrument or its sensors with solvents or products that contain solvents.
  • Page 3 Figure 2. Gas Ports 4. Overview of Standard EN7967 IMPORTANT: The CO Appliance Kit (P/N 0024-8555) is intended to be used in accordance with the carbon monoxide standard EN7967 which provides specific guidelines for identifying and managing sources of hazardous combustion byproducts.
  • Page 4 CO Appliance Kit Step Description Check the probe’s filter for signs of soot and/or moisture. Replace if necessary. Attach the desired probe to the probe handle. Attach the probe tubing to the GAS inlet on the bottom of the instrument. Use the female gas ...

Table of Contents