Parameter
Implicit
Message
Output
Period
Elevation mask angle
File name prefix
FN key mode
Initial dynamic mode
Click Apply every time after the parameter was
Note:
changed, otherwise the receiver won't save the changes. Click
Refresh, to ensure the changed parameters and new configura-
tion are saved.
Figure 5.
Figure 6.
5. Open Positioning tab and set the Elevation
mask to 15 degrees .
16
Base
Rover
15 seconds
15 degrees
Enter a unique ID, such as the last 3 digits
of receiver's serial number. By deafault the
prefix is log
(starts/stops the data recording when FN
button is used)
Select
LED
blink
Select
Occupation
mode
switch
for
mode
switch
Static data
RTK)
-
Select Dynamic (for
trajectory survey)
Log Files tab
TriPad tab
(for
Figure 7.
6. To set up the base station, open the Base tab and
set the following parameters: Antenna Phase Center
Position (APC) - enter latitude, longitude, and altitude
(ellipsoidal height) values of the antenna position. Do
one of the following:
• If known, type in the values.
• Click Get from receiver to use the current antenna
position.
7. Restart your receiver. Open the Base tab and
check coordinates. Click Refresh, to refresh the pa-
rameters.
7. To set up the rover, open Positioning tab and set
the Position Computation Mode - this drop-down list
box allows selecting the mode of position computa-
Elevation mask
Base tab
Figure 8.
www.javad.com
Need help?