Symptom
Cause
XRS EID Stick
New Session On Power
Reader only:
Up has been set to On.
The stick reader
starts a new
session each time
the stick reader is
switched on.
XRS EID Stick
Stick reader memory is full.
Reader only:
Scanning records
being over-written.
XRS EID Stick
Real time clock battery may
Reader only:
be faulty
Session data is not
saved when the
stick reader is
switched off.
XRS EID Stick
Real time clock battery may
Reader only:
be faulty
The internal date is
reset each time the
stick reader is
switched off.
Issue 2, 02/2013
Solution
Disable New Session On Power Up. See Changing the
stick reader settings using EziLink on page 33 (Data tab,
New Session On Power Up setting).
When the stick reader‟s memory is full (20,000 scan
capacity), the stick reader will begin to overwrite the
oldest scan records.
Transfer sessions to a PC using EziLink. See Backing
up customer data on page 22. Clear unwanted session
data from the stick reader. See Deleting all sessions,
VID-EID pairs and alerts on the stick reader on page 33.
Replace the real time clock battery. See page 31.
Replace the real time clock battery. See page 24.