Capacity
Herd capacity
7 gal
75 horses, 75 beef
27 L
75 horses, 75 beef
Capacidad
Rebaño máx.
7 galones
75 caballos, 75 reses
27 l
75 caballos, 75 reses
Drinking height
Net weight
21.65 inches
550 mm
Altura para beber
Peso neto
21,65 pulgadas
59,5 libras
550 mm
59.5 lbs
27 kg
27 kg
1

Advertisement

Table of Contents
loading

Summary of Contents for Tru-Test WaterPro 2

  • Page 1 USER GUIDE Capacity Herd capacity Drinking height Net weight 7 gal 75 horses, 75 beef 21.65 inches 59.5 lbs 27 L 75 horses, 75 beef 550 mm 27 kg Capacidad Rebaño máx. Altura para beber Peso neto 7 galones 75 caballos, 75 reses 21,65 pulgadas 59,5 libras 27 l...
  • Page 2: Table Of Contents

    Contents Safety warnings..................................3 Warranty registration ................................3 Before you start..................................4 WaterPro2 measurements ..............................4 Basic concrete slab measurements ............................ 4 Concrete and tank hole alignment ............................ 5 Unpacking the box ..................................5 Recommended parts ................................. 5 Recommended tools ................................5 Included parts ...................................
  • Page 3: Safety Warnings

    Tru-Test Limited. Tru-Test Limited reserves the right at any time to change characteristics or specifications without notice. All trademarks with an * are neither owned by nor licensed to Tru-Test Limited and belong to their respective owners. 833400 Issue 5 1/2018...
  • Page 4: Before You Start

    Before you start Measure out the dimensions of the concrete slab that you will need. Length x Width x Overall Height Length x Width x Overall Height WaterPro2 39.2 x 22.1 x 28.7 inches 996 x 563 x 730 mm WaterPro2 measurements Basic concrete slab measurements...
  • Page 5: Concrete And Tank Hole Alignment

    Concrete and tank hole alignment Check your measurements to ensure that the opening on the bottom of the tank aligns with the thermal earth tube placement in the concrete. The opening on the bottom of the tank is off center. Ensure that the water supply lines are not touching the sides of the thermal earth tube.
  • Page 6: Included Parts

    Included parts Get to know the parts of the WaterPro2 before you install it. Contact us on 800 874 8494 if anything is missing. Images are indicative of shipped part and not shown to scale.
  • Page 7: Installation

    Installation Cross-section of final installation The WaterPro2 is designed to provide reliable fresh water to your livestock all year round. When installing the WaterPro2 pay attention to the following areas: Choose a location where the tank will be sheltered from the elements. •...
  • Page 8: Step 1: Preparing The Site

    Have you turned off the water? Step 1: Preparing the site Choose a location that is easily accessible by livestock and sheltered from the elements. Concrete and tank hole Check the measurements of your WaterPro2 against the size of the concrete slab you need. See alignment on page 5.
  • Page 9: Step 3: Installing The Electric Service For The Heat Immersion Cable

    Step 3: Installing the electric service for the heat immersion cable If you are installing the WaterPro2 in an area that experiences freezing temperatures, you may wish to install an immersion heater (part 832381). Arrange for your electrician to install the electric service around the same time you are installing the water supply lines. Install the electric service outside of the thermal earth tube on the horizontal side under one of the water reservoirs.
  • Page 10: Step 6: Preparing The Vertical Water Supply Line And Checking For Leaks

    Critical step please follow these instructions carefully Step 6: Preparing the vertical water supply line and checking for leaks In Step 2, the vertical water supply line was cut to be approximately 10 inches (254 mm) above the concrete slab. In this step, you will add the NPT fitting and any adapters needed first, measure and then cut it to a precise length.
  • Page 11 Take the measurement and subtract 8.75 inches (222.3 mm) from this number. This is the amount of pipe you will need to cut. Remove all adapters and fittings from the vertical water supply line. From the top down, mark the pipe with the measurement you need to cut. Cut the pipe. Attach any adapters and the ½...
  • Page 12: Step 7: Preparing The Tank

    Step 7: Preparing the tank Turn the tank on its side. Apply the foam tape to the bottom of the tank, around the outside edge (in the recessed channel shown in red below). Lift the tank and carefully position it over the vertical water supply line. Attach the ½...
  • Page 13: Pressure And Flow Capacity

    Pressure and flow capacity You may need to install a pressure reducer on the vertical water supply line in hilly areas where the water pressure is affected. WaterPro2 Flow (Gal/min) Flow (L/min) 14.5 15.1 18.3 43.5 21.5 72.5 MAX 26.8 Using the shut-off valve as a pressure reducer If high water pressure is an issue, the shut-off valve can be used to help reduce the flow of water into the valve.
  • Page 14: Recommendations

    Recommendations Split fence measurements The WaterPro2 can also be used to split two pastures or pens with a fence line separating the drinking area. This allows livestock from both sides of the fence to have access to water. Check that you have enough clearance between the float reservoir lid and fence so that you can remove the lid to get to the valve and float assembly.
  • Page 15: Troubleshooting

    Troubleshooting Symptom Possible cause/s Solution/s to check or action: Water frozen in tank Water frozen in lines or Vertical water supply line is properly insulated. connections. Tank bottom is sealed on concrete. Livestock are drinking from the WaterPro2, if not, drain and refill to recycle fresh water.
  • Page 16: Spare Parts

    Spare parts The parts below are available to order from your local Tru-Test WaterPro2 supplier. Images are indicative of spare part and not shown to scale. Panel door Spare panel door fastener kit Float reservoir lid 832895P 832894P 832892P Excludes hardware and fastener kit...
  • Page 17: Valve And Float

    Valve and float...
  • Page 18: Product Warranty

    This warranty applies only to genuine Tru-Test products manufactured by or for Tru-Test, Inc. The liability of Tru-Test, Inc. under this warranty is excluded to the extent that any defect has been caused or contributed to by: Any accident, contamination, tampering, modification, willful damage, improper storage, improper use or negligent act of, or by omission by, any person other than Tru-Test, Inc.;...
  • Page 19 Advertencias de seguridad ..............................20 Registro de la garantía ................................20 Antes de comenzar ................................. 20 Dimensiones del WaterPro2 ............................20 Dimensiones de una losa de concreto básica ........................20 Alineación del concreto con el agujero del tanque ......................21 Instrucciones de desempacado ...............................
  • Page 20 Envíenos sus datos para poder registrar su producto y mantenerlo informado de cualquier actualización importante. Más información en livestock.tru-test.com/en-us/livestock-waterer-warranty-registration-form Mida las dimensiones de la losa de concreto que necesitará. Longitud x Ancho x Altura total...
  • Page 21 Revise las medidas para garantizar que la apertura en el fondo del tanque se alinea con la ubicación del tubo térmico subterráneo en el concreto. La apertura en el fondo del tanque no está centrada. Asegúrese de que las tuberías de suministro de agua no tocan los lados del tubo térmico subterráneo. En climas fríos, recomendamos el uso de uno más tubos térmicos subterráneos para evitar que la tubería de agua vertical ...
  • Page 22 Familiarícese con las partes del WaterPro2 antes de instalarlo. En caso de que falte alguna parte, póngase en contacto con nosotros a través del 800 874 8494. Las imágenes indican solo lo que se incluye y no están a escala.
  • Page 23 El WaterPro2 está diseñado para suministrar agua fresca a sus animales de manera confiable durante todo el año. Al instalar el WaterPro2, preste especial atención a las siguientes áreas: Elija una ubicación donde el tanque esté lo más resguardado del clima. ...
  • Page 24 ¿Ha cerrado la llave de paso de agua? Elija una ubicación que los animales puedan acceder con facilidad y que cuente con protección del clima. Alineación Revise las dimensiones del WaterPro2 en relación con el tamaño de la losa de concreto que necesita. Consulte del concreto con el agujero del tanque en la página 21.
  • Page 25 Si instala el WaterPro2 es un área donde se producen temperaturas de congelamiento, es posible que quiera instalar un calentador de inmersión (número de pieza 832381). Coordine con su electricista para que instale el suministro eléctrico alrededor del mismo momento que instale las tuberías de suministro de agua.
  • Page 26 Paso muy importante: Siga estas instrucciones cuidadosamente. En el Paso 2, la tubería de suministro vertical de agua se cortó aproximadamente a 254 mm sobre la losa de concreto. En este paso, agregará primero el conector NPT y los adaptares que pudiera necesitar, medirá de nuevo y cortará a la longitud precisa. Para facilitar la instalación, la tubería de suministro vertical de agua, junto con todos los conectores y adaptadores, debe medir exactamente 222,3 mm desde el tope del concreto hasta su extremo.
  • Page 27 Tome esta medida y réstele 222,3 mm. Esta es la longitud de la tubería que debe cortar. Retire todos los adaptadores y conectores de la tubería de suministro vertical de agua. De la parte superior hacia abajo, marque la tubería con la medida debe cortar. Corte la tubería. Fije los adaptadores y el conector de ½...
  • Page 28 Voltee el tanque sobre un costado. Aplique la cinta de espuma al fondo del tanque, alrededor del borde exterior (en el canal encastrado, que se muestra en rojo a continuación). Levante el tanque y ubíquelo con cuidado sobre la tubería de suministro vertical de agua. Conecte la tubería flexible de ½...
  • Page 29 Es posible que tenga que instalar un reductor de presión en la tubería de suministro vertical de agua en caso de que esté ubicado en una zona montañosa, donde la presión del agua sea mayor. WaterPro2 Flujo (Gal/min) Flujo (L/min) 14,5 15,1 18,3...
  • Page 30 El WaterPro2 puede usarse para dividir dos pastizales o corrales con una cerca que separe el área de suministro de agua. Esto permite que los animales de ambos lados de la cerca puedan acceder al agua. Revise que haya suficiente espacio entre la tapa del depósito del flotador y la cerca, de forma que pueda retirarla y acceder al montaje de válvula y flotador.
  • Page 31 Síntoma Posibles causas Soluciones a revisar o medidas que puede tomar: Agua congelada en Agua congelada en las tuberías o La tubería de suministro vertical de agua está debidamente el tanque conexiones. aislada. El fondo del tanque está sellado en el concreto. Los animales están bebiendo del WaterPro2;...
  • Page 32 Las piezas a continuación están disponibles en su distribuidor local Tru-Test de WaterPro2. Las imágenes indican solo las piezas de repuesto disponibles y no están a escala. Puerta del panel Kit de ajuste de la puerta del panel Tapa del depósito del flotador...
  • Page 34 Las responsabilidades de garantía de Tru-Test, Inc. para Productos de suministro de agua automáticos para animales de crianza fabricados por o para Tru-Test, Inc. están limitadas a los términos en la presente política. Tru-Test, Inc. garantiza que sus productos están libres de defectos en materiales y mano de obra durante los periodos descritos a continuación.

Table of Contents