Honeywell Excel 800 SYSTEM Installation And Commissioning Instructions page 87

Table of Contents

Advertisement

Excel 800
Temp.
Resistance
Terminal
[°C]
voltage [V]
[
190.0
1722
0.647
191.0
1725
0.648
192.0
1729
0.649
193.0
1733
0.651
194.0
1736
0.652
195.0
1740
0.653
196.0
1744
0.655
197.0
1747
0.656
198.0
1751
0.657
199.0
1755
0.658
200.0
1758
0.659
201.0
1762
0.661
202.0
1766
0.662
203.0
1769
0.663
204.0
1773
0.665
205.0
1777
0.666
206.0
1780
0.667
207.0
1784
0.669
208.0
1788
0.670
209.0
1791
0.671
210.0
1795
0.672
211.0
1799
0.674
212.0
1802
0.675
213.0
1806
0.676
214.0
1810
0.678
215.0
1813
0.679
216.0
1817
0.680
217.0
1821
0.681
218.0
1824
0.683
219.0
1828
0.684
220.0
1832
0.685
221.0
1835
0.686
222.0
1839
0.688
223.0
1843
0.689
224.0
1846
0.690
225.0
1850
0.692
226.0
1854
0.693
227.0
1857
0.694
228.0
1861
0.695
229.0
1865
0.697
230.0
1868
0.698
231.0
1872
0.699
232.0
1875
0.700
233.0
1879
0.702
234.0
1883
0.703
235.0
1886
0.704
236.0
1890
0.705
237.0
1894
0.707
238.0
1897
0.708
239.0
1901
0.709
240.0
1905
0.711
241.0
1908
0.712
242.0
1912
0.713
243.0
1915
0.714
244.0
1919
0.716
245.0
1923
0.717
246.0
1926
0.718
247.0
1930
0.719
248.0
1934
0.721
249.0
1937
0.722
Temp.
Resistance
Terminal
[°C]
voltage [V]
[
250.0
1941
0.723
251.0
1944
0.724
252.0
1948
0.726
253.0
1952
0.727
254.0
1955
0.728
255.0
1959
0.729
256.0
1962
0.730
257.0
1966
0.732
258.0
1970
0.733
259.0
1973
0.734
260.0
1977
0.736
261.0
1980
0.737
262.0
1984
0.738
263.0
1988
0.739
264.0
1991
0.740
265.0
1995
0.742
266.0
1998
0.743
267.0
2002
0.744
268.0
2006
0.746
269.0
2009
0.747
270.0
2013
0.748
271.0
2016
0.749
272.0
2020
0.750
273.0
2024
0.752
274.0
2027
0.753
275.0
2031
0.754
276.0
2034
0.755
277.0
2038
0.757
278.0
2042
0.758
279.0
2045
0.759
280.0
2049
0.760
281.0
2052
0.761
282.0
2056
0.763
283.0
2060
0.764
284.0
2063
0.765
285.0
2067
0.766
286.0
2070
0.768
287.0
2074
0.769
288.0
2077
0.770
289.0
2081
0.771
290.0
2085
0.773
291.0
2088
0.774
292.0
2092
0.775
293.0
2095
0.776
294.0
2099
0.777
295.0
2102
0.778
296.0
2106
0.780
297.0
2110
0.781
298.0
2113
0.782
299.0
2117
0.784
300.0
2120
0.785
301.0
2124
0.786
302.0
2127
0.787
303.0
2131
0.788
304.0
2134
0.789
305.0
2138
0.791
306.0
2142
0.792
307.0
2145
0.793
308.0
2149
0.794
309.0
2152
0.796
87
Appendix 3: Sensor Characteristics
Temp.
Resistance
Terminal
[°C]
voltage [V]
[
310.0
2156
0.797
311.0
2159
0.798
312.0
2163
0.799
313.0
2166
0.800
314.0
2170
0.802
315.0
2173
0.803
316.0
2177
0.804
317.0
2181
0.805
318.0
2184
0.806
319.0
2188
0.808
320.0
2191
0.809
321.0
2195
0.810
322.0
2198
0.811
323.0
2202
0.812
324.0
2205
0.814
325.0
2209
0.815
326.0
2212
0.816
327.0
2216
0.817
328.0
2219
0.818
329.0
2223
0.820
330.0
2226
0.821
331.0
2230
0.822
332.0
2234
0.823
333.0
2237
0.824
334.0
2241
0.826
335.0
2244
0.827
336.0
2248
0.828
337.0
2251
0.829
338.0
2255
0.830
339.0
2258
0.831
340.0
2262
0.833
341.0
2265
0.834
342.0
2269
0.835
343.0
2272
0.836
344.0
2276
0.838
345.0
2279
0.839
346.0
2283
0.840
347.0
2286
0.841
348.0
2290
0.842
349.0
2293
0.843
350.0
2297
0.845
351.0
2300
0.846
352.0
2304
0.847
353.0
2307
0.848
354.0
2311
0.849
355.0
2314
0.850
356.0
2318
0.852
357.0
2321
0.853
358.0
2325
0.854
359.0
2328
0.855
360.0
2332
0.856
361.0
2335
0.857
362.0
2339
0.859
363.0
2342
0.860
364.0
2346
0.861
365.0
2349
0.862
366.0
2353
0.863
367.0
2356
0.864
368.0
2360
0.866
369.0
2363
0.867
Temp.
Resistance
Terminal
[°C]
voltage [V]
[
370.0
2367
0.868
371.0
2370
0.869
372.0
2373
0.870
373.0
2377
0.871
374.0
2380
0.872
375.0
2384
0.874
376.0
2387
0.875
377.0
2391
0.876
378.0
2394
0.877
379.0
2398
0.878
380.0
2401
0.879
381.0
2405
0.881
382.0
2408
0.882
383.0
2412
0.883
384.0
2415
0.884
385.0
2419
0.885
386.0
2422
0.886
387.0
2426
0.888
388.0
2429
0.889
389.0
2432
0.890
390.0
2436
0.891
391.0
2439
0.892
392.0
2443
0.893
393.0
2446
0.894
394.0
2450
0.896
395.0
2453
0.897
396.0
2457
0.898
397.0
2460
0.899
398.0
2463
0.900
399.0
2467
0.901
400.0
2470
0.902
EN1B-0375GE51 R0910