Esc+Fw Rule / Grid Print - SATO WS4 Series Programming Reference Manual

Hide thumbs Also See for WS4 Series:
Table of Contents

Advertisement

Modification
Available for
WS4 series

ESC+FW Rule / Grid Print

Rule / Grid Print
ESC
Hex code
<1B>
16
Default setting
None
When printer is powered off
Persistence of
Validity in a job
the command
Validity after a job
[Function]
Prints rule / grid
[Format]
<FW>aabcccc
● Parameter
a
[Line width]
b
[Horizontal / vertical setting]
c
[Length]
<FW>aabbVccccHdddd
● Parameter
a
[Vertical line width]
b
[Horizontal line width]
c
[Vertical line length]
d
[Horizontal line length]
[Coding example]
Ruled line:
Grid:
<A>
<V>100<H>200<FW>04H400
<V>300<H>200<FW>0808V300H400
<Q>2
<Z>
[Notes]
1. If the print start position is outside of the printable area, it will not print due to a command error.
[Valid range]
Model
WS408DT/TT
WS412DT/TT
FW
<46>
<57>
16
16
Set parameter will not be retained
Becomes invalid after execution
Becomes invalid after the job
=
=
=
=
=
=
=
Line width: 4,
Horizontal setting, Length: 400
V. line width: 8,
H. line width: 8, V. line length: 300, H. line length: 400
Horizontal line length in dots
1 to 832
1 to 1248
ESC+FW
Parameter
Rule aabcccc
Grid aabbVccccHdddd
Rule print
Valid range
:
02 to 99 dots
H
:
Horizontal
V
:
Vertical
Valid range
:
Refer to table below
Grid print
Valid range
:
02 to 99 dots
Valid range
:
02 to 99 dots
Valid range
:
Refer to table below
Valid range
:
Refer to table below
Vertical line length in dots
1 to 7992
1 to 11988
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws408dtWs412dtWs408ttWs412tt

Table of Contents