Assembling The Breast Pump - Philips AVENT SCF334 Manual

Hide thumbs Also See for SCF334:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
English
12

Assembling the breast pump

Note: Make sure you have cleaned and sanitized the appropriate parts of the breast pump.
1 Wash your hands thoroughly before you handle the cleaned parts.
Warning: Be careful, the cleaned parts may still be hot. Only start assembling the
breast pump when cleaned parts have cooled down.
Note: You may find it easier to assemble the breast pump while it is wet.
2 Insert the white valve into the pump body from underneath. Push the valve in as far as possible
(Fig. 9).
3 Screw the pump body clockwise onto the bottle until it is securely fixed (Fig. 10).
4 Insert the silicone diaphragm into the pump body from above. Make sure it fits securely around the
rim by pressing down with your fingers to ensure a perfect seal (Fig. 11).
5 Insert the cushion into the funnel-shaped section of the pump body (Fig. 12).
6 Push in the inner part of the cushion as far as possible and make sure that it is perfectly sealed all
around the rim of the pump body (Fig. 13).
7 Press in between the petals to remove any trapped air (Fig. 14).
Note: Place the cover over the cushion to keep the breast pump clean while you prepare for
expressing.
Warning: Always use the breast pump with a cushion.
8 Insert the adapter into the wall socket and insert the plug at the other end into the motor unit
(Fig. 15).
The adapter reference code is indicated on the bottom of the appliance. Only use the indicated
adapter with the appliance.
-
For battery operation (single electric breast pump only), turn the bottom of the motor unit in
the direction indicated by the marks on the bottom (step 1 (Fig. 16)) and remove it (step 2
(Fig. 16)). Insert four new 1.5V AA batteries (or 1.2V, in case of rechargeable batteries) into the
battery housing. Check the markings on the housing of the battery for the correct polarity.
Reattach the bottom to the motor unit.
Note: A new set of batteries provides 1-3 hours of operating time. Rechargeable batteries will lose
capacity over time and may cause a decrease in operating time.
Note: If you have inserted batteries in the battery housing of the motor unit and plug in the adapter,
the breast pump will run from on electrical power. The batteries cannot be charged in the unit.
Warning: Do not mix different type of batteries.
Warning: Do not mix used and new batteries.
9 Attach the silicone tube and cap onto the diaphragm. Push down the cap until it is securely in
place (Fig. 17).