(In Vehicle Test) - 24V System Test; System Test Results - Midtronics CPX-950 EU User Manual

Battery & electrical diagnostic analyzer for 12-volt automotive batteries and 24v systems
Table of Contents

Advertisement

3 - 24V System
Test Results - Bat. 1
Rated
Voltage
1
Measured
Good Battery
Battery Type:
Temperature:

Send Results
Test Results - Battery Test
To send the test results select Send Results. To continue to further testing the 24V batteries, select
System Test. To return to the Home Screen, select Done to return to the main screen.

(In Vehicle test) - 24V System Test

1.
Select External Amp Clamp or No Amp Clamp. Midtronics recommends to use the PDF40
external amp clamp.
2.
Start the vehicle's engine and leave it running.
Ensure all accessories (High Beam headlights/ventilation blower etc.) are off and select Next.
3.
The analyzer tests the alternator output.
4.
When prompted, rev and hold the engine to between 1000 to 1250 rpm.
The analyzer tests the alternator output again.
When prompted Idle the engine and and select Next.
5.
6.
Turn on the high beam headlights and ventilation blower.
7.
Select Next.
The analyzer tests the alternator output.
8.
When prompted, rev and hold the engine to between 1000 to 1250 rpm.
The analyzer tests the alternator output again.
9.
When prompted Idle the engine, turn off loads, then turn off ingition and select Next.
10. If an external amp clamp was used, the tester now asks the measured drain current. Insert the
number, then select Next.
11. The results are shown.

System Test Results

Test Results - Summary
Good Battery
Cranking Normal
Charging Normal
Send Results
14
575 CCA
12.72 V
599 CCA
SLI
24 C
Done
Done
Midtronics BV Hoofdveste 6-8 3992DG Houten
CPX-950
CPX-950
The Test Results - Summary screen is displayed following a System Test. Select the Battery,
Cranking, or Alternator Test to view detailed test results for each part of the test. Refer to Appendix
B: Decision Tables for a complete explaination of the possible test results.
To send the test results to a configured printer or via email select Send Results. To return to the
Home Screen, select Done to the Main Menu
www.midtronicseurope.com
Test Results - Summary
3 - 24V System
15