Parameters; What This Chapter Contains; Terms And Abbreviations; Summary Of Parameter Groups - ABB DCS880 Quick Manual

Hide thumbs Also See for DCS880:
Table of Contents

Advertisement

Parameters

What this chapter contains

The chapter describes the parameters and signals of the firmware.

Terms and abbreviations

Term
Definition
Signal
Type of parameter that is the result of a measurement or calculation by the drive, or
contains status information. Most signals are read-only, but some (especially counter-type
signals) can be reset.
Default (def.)
The default value of a parameter.
Scale/Fbeq16
16-bit fieldbus equivalent: The scaling between the value shown on the panel and the
integer used in communication when a 16-bit value is selected for transmission to an
external system.
A dash (-) indicates that the parameter is not accessible in 16-bit format.
Other
The value is taken from another parameter.
Choosing "Other" displays a parameter list in which the user can specify the source
parameter.
Other [bit]
The value is taken from a specific bit in another parameter.
Choosing "Other" displays a parameter list in which the user can specify the source
parameter and bit.
Parameter
A user-adjustable operating instruction for the drive.
p.u.
Per unit

Summary of parameter groups

Group
01 Actual values
03 Input references
04 Warnings and faults
05 Diagnostics
06 Control and status words
07 System info
10 Standard DI, RO
11 Standard DIO, FI, FO
12 Standard AI
13 Standard AO
14 I/O extension module 1
15 I/O extension module 2
16 I/O extension module 3
19 I/O Operation mode
20 Start/Stop/Direction
21 Start/Stop mode
22 Speed reference selection
23 Speed reference ramp
24 Speed reference conditioning
25 Speed control
26 Torque reference chain
27 Armature current control
28 EMF and field current control
29 12-pulse/Hardparallel
30 Control limits
Contents
Basic signals for monitoring the drive.
Values of references received from various sources.
Information on warnings and faults that occurred last. For explanations of
individual warning and fault codes.
Various run-time-type counters and measurements related to drive
maintenance.
Drive control, status and event words.
The drive's hardware and firmware information.
Configuration of digital inputs and relay outputs.
Configuration of digital input/outputs and frequency inputs/outputs.
Configuration of standard analog inputs.
Configuration of standard analog outputs.
Configuration of I/O extension module 1.
Configuration of I/O extension module 2.
Configuration of I/O extension module 3.
Selection of local and external control locations and operating modes.
Start/Stop/Direction and run/start/jog enable signal source selection.
Positive/Negative reference enable source selection. Breaker and
acknowledge source selection.
Start and stop modes, emergency stop mode and zero speed.
Speed reference selection and motor potentiometer settings.
Speed reference ramp settings (programming of the acceleration and
deceleration rates for the drive).
Speed error calculation, speed error window control configuration and
speed error (Δn) step.
Speed controller settings.
Settings for the torque reference chain.
Settings for the armature current control chain.
Settings for the EMF and field current control chain.
Settings for 12-pulse and hardparallel.
Drive operation limits.
3ADW000480R0101 DCS880 Quick guide e a
25
Parameters

Hide quick links:

Advertisement

Table of Contents