ABB DCS880 Quick Manual page 26

Hide thumbs Also See for DCS880:
Table of Contents

Advertisement

26
31 Fault functions and fault levels
32 Supervision
33 Generic timer & counter
35 Motor thermal protection
36 Load analyzer
37 User load curve
40 Process PID
42 Shared motion (2nd motor)
44 Mechanical brake control
45 Energy efficiency
46 Monitoring/Scaling settings
47 Data storage
49 Panel port communication
50 Fieldbus adapter (FBA)l
51 FBA A settings
52 FBA A data in
53 FBA A data out
54 FBA B settings
55 FBA B data in
56 FBA B data out
58 Embedded fieldbus
60 DDCS Communication
61 D2D and DDCS transmit data
62 D2D and DDCS receive data
70 DCSLink Communication
74 ... 89 Application specific
groups
90 Feedback selection
91 Encoder module settings
92 Encoder 1 configuration
93 Encoder 2 configuration
94 OnBoard speed feedback
configuration
95 HW configuration
96 System
99 Motor data
Parameters
Configuration of external events. Selection of the drive behavior in fault
situations.
Configuration of signal supervision functions 1 ... 3. Three values can be
monitored. A warning or fault is generated whenever predefined limits are
exceeded.
Configuration of maintenance timers/counters.
Motor thermal protection settings such as temperature measurement
configuration and load curve definition.
Peak value and amplitude logger settings.
Settings for user load curve.
Parameter values for process PID controller.
Configuration of 2
motor.
nd
Configuration of mechanical brake.
Settings for the energy saving calculators.
Speed supervision settings, signal filtering and general scaling settings.
Data storage parameters that can be written to and read from using other
parameters' source and target settings.
Communication settings for the control panel port on the drive.
Fieldbus communication configuration.
Fieldbus adapter A configuration.
Selection of data sent by fieldbus adapter A to the master (e.g. PLC).
Selection of data sent by the master (e.g. PLC) to fieldbus adapter A.
Description see group 51 FBA A settings.
Description see group 52 FBA A data in.
Description see group 53 FBA A data out.
Embedded fieldbus (EFB) configuration.
DDCS communication configuration.
Defines the data sent from the drive to the DDCS/D2D link.
Defines the data sent from the DDCS/D2D link to the drive.
Defines the DCSLink communication.
Groups used for application programming.
Motor and load feedback configuration.
Configuration of the encoder interface modules.
Settings for encoder 1.
Settings for encoder 2.
Settings for analog tacho and OnBoard encoder.
Various hardware-related settings.
Language selection; access levels; macro selection; parameter save and
restore; control board reboot; user parameter sets; unit selection; data
logger triggering; parameter checksum calculation; user lock.
Motor configuration settings.
3ADW000480R0101 DCS880 Quick guide e a

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents