General Data - Trane PKG-PRC002-EN Manual

Trane 20-80 ton water-cooled air conditioners 20-60 ton air-cooled air conditioners remote air-cooled condensers manual pkg-prc002-en intellipak signature series
Table of Contents

Advertisement

Table GD-1. SCWF/SIWF Water-Cooled Self-Contained, 20-38 Tons
Unit Size
20
Compressor Data
Quantity
2
NominalTon/Comp
10
Circuits
2
Evaporator Coil Data
Rows
2
Sq. Ft.
21.81
Sq. m
(2.03)
FPF
144
Condenser Data
Minimum GPM w/o Econ
36
Minimum liters / sec. w/o Econ
(2.27)
Minimum GPM w/ Econ
41
Minimum liters / sec. w/ Econ
(2.59)
Maximum GPM
80
Maximum liters / sec.
(5.05)
Evaporator Fan Data
Quantity
1
Size (Dia. - inches)
16.5"
Size (Dia. - mm)
(419.1)
Minimum HP
5
Minimum kW
(3.73)
Maximum HP
20
Maximum kW
(14.91)
Minimum Design CFM
6325
Minimum Design liter / sec.
(2985)
Maximum Design CFM
8500
Maximum Design liter / sec.
(4012)

General Data

EER
12.9
IPLV
13.6
Refrigerant Charge - lbs. R-22
Circuit A
24
Circuit B
24
Circuit C
Refrigerant Charge - kg R-22
Circuit A
(10.9)
Circuit B
(10.9)
Circuit C
Capacity Steps - %
100/53/0
Filter Data
Quantity
8
Size (inches)
20x18x2
Size (mm)
(508 X 457 X 51)
Quantity
4
Size (inches)
20x20x2
Size (mm)
(508 X 508 X 51)
Notes:
1. Compressors are Trane 3D
®
scroll.
2. EER and IPV are rated in accordance to the ARI Standard 340/360-93. Based on 80/67 F (26.7/19.4 C) to the evaporator coil,
nominal airflow and 85-95 F (29.4/35 C) condenser water.
3. All units operate with R-22. Units ships with full operating charge.
4. Maximum cfm limits are set to prevent moisture carryover on the evaporator coil.
5. Minimum cfm limits are set to ensure stable thermal expansion valve operation at low load conditions.
6. Filter sizes are for units without hot water or steam heating coils.
PKG-PRC002-EN
General Data
22
25
2
10
10
2
2
21.81
21.81
(2.03)
(2.03)
144
144
36
36
(2.27)
(2.27)
41
41
(2.59)
(2.59)
80
80
(5.05)
(5.05)
1
16.5"
16.5"
(419.1)
(419.1)
5
(3.73)
(3.73)
20
20
(14.91)
(14.91)
6325
6500
(2985)
(3068)
9350
10625
(4413)
(5014)
12.6
13.4
12.9
13.6
24
24
24
24
-
-
(10.9)
(10.9)
(10.9)
(10.9)
-
-
100/53/0
100/53/0
8
20x18x2
20x18x2
(508 X 457 X 51)
(508 X 457 X 51)
4
20x20x2
20x20x2
(508 X 508 X 51)
(508 X 508 X 51)
29
2
1/1
15/10
15/10
2
2
3
2
29.98
29.98
(2.79)
(2.79)
144
46
(2.9)
(2.9)
60
(3.79)
(3.79)
102
(6.44)
(6.44)
1
1
18.25"
18.25"
(463.6)
(463.6)
5
5
(3.73)
(3.73)
25
(18.64)
(18.64)
8700
8700
(4106)
(4106)
12325
13600
(5817)
(6418)
14.1
13.6
14.5
13.0
28
24
-
-
(12.7)
(13.6)
(10.9)
(11.3)
-
-
100/62/39/0
100/59/39/0
8
8
20x18x2
20x18x2
(508 X 457 X 51)
(508 X 457 X 51)
4
4
20x20x2
20x20x2
(508 X 508 X 51)
(508 X 508 X 51)
SCWF/SIWF
20-38 Tons
32
35
1/1
3
10
2
3
4
3
31.35
31.35
(2.91)
(2.91)
144
120
46
54
(3.41)
(3.41)
60
65
(4.1)
(4.1)
102
119
(7.51)
(7.51)
1
1
20"
(508)
(508)
5
5
(3.73)
(3.73)
25
25
(18.64)
(18.64)
9100
9880
(4295)
(4663)
14875
16150
(7020)
(7622)
13.3
13.4
12.8
12.4
30
24
25
24
-
24
(10.9)
(11.3)
(10.9)
(11.3)
-
(10.9)
(11.3)
100/65/31/0
100/65/30/0
8
8
20x18x2
20x18x2
(508 X 457 X 51)
(508 X 457 X 51)
4
4
20x20x2
20x20x2
(508 X 508 X 51)
(508 X 508 X 51)
Table GD-2. SCWF/SIWF Refrigerant Circuits,
Number of Compressors by Circuit
Circuit 1
2
Unit Size
20/22/25 Ton
1- 10T 1- 10T
29/32 Ton
1- 15T 1- 10T
35/38 Ton
1- 10T 1- 10T 1- 10T
42/46 Ton
1- 15T 1- 10T 1- 10T
52/58 Ton
1- 15T 1- 15T 1- 15T
60/72 Ton
1- 15T 1- 15T 1- 15T 1- 10T
80 Ton
1- 15T 1- 15T 1- 15T 1- 15T
Note: This table depicts compressor location in unit, plan
view from left corner.
38
3
10
3
4
144
54
65
119
1
20"
5
25
25
25
25
8
4
3
4
17