Installation,
Operation, and
Maintenance
Packaged Terminal Air
Conditioner
PTEE070/PTHE070 (7 ,000 Btuh)
PTEE090/PTHE 090 (9,000 Btuh)
PTEE120/PTHE120 (12,000 Btuh)
PTEE150/PTHE150 (15,000 Btuh)
September 2006
PTAC-SVX01C-EN

Advertisement

Table of Contents
loading

Summary of Contents for Trane PTAC-SVX01C-EN

  • Page 1 Installation, Operation, and Maintenance Packaged Terminal Air Conditioner PTEE070/PTHE070 (7 ,000 Btuh) PTEE090/PTHE 090 (9,000 Btuh) PTEE120/PTHE120 (12,000 Btuh) PTEE150/PTHE150 (15,000 Btuh) September 2006 PTAC-SVX01C-EN...
  • Page 2: Table Of Contents

    ... . 38 ..41 ..41 ....50 PTAC-SVX01C-EN...
  • Page 3: Model Number Description

    12,000 Btu 150 = 15,000 Btu Electric heater Front and discharge grille Indoor coil PTAC-SVX01C-EN Model Number Description The model number helps owner/ operator, installing contractors, and service technicians to define the operation, components and options for a specific unit.
  • Page 4: General Information

    CAUTION Use Copper Conductors Only! Unit terminals are not designed to accept other types of conductors. Failure to use copper conductors may result in equipment damage. PTAC-SVX01C-EN...
  • Page 5 Obtain a chemical analysis of the refrigerant if necessary. Questions about recovered refrigerant and acceptable refrigerant quality standards are addressed in ARI Standard 700. PTAC-SVX01C-EN General Information Refrigerant Handling and Safety Consult the manufacturer’s material safety data sheet (MSDS) for...
  • Page 6: Pre-Installation

    • Ensure adequate sealing and insulation is around the wall sleeve. Figure 2. Minimum unit clearance Table 1. Minimum interior and exterior projections 42 1/2” min. 16 1/4” min. Finished Floor Dimension B Figure 3. Minimum wall opening dimensions PTAC-SVX01C-EN...
  • Page 7: Table 2. Minimum Clearances And Projections

    Remove access panels and check for interior component damage. Make specific notations concerning the damage on the freight bill. Do not accept delivery. PTAC-SVX01C-EN Pre-Installation Minimum projection 3 1/4 2 3/4 8 (4) 2-6” 50 -150 76-80 •...
  • Page 8: Unit Dimensions

    Figure 4. Unit with wall sleeve and subbase accessory Figure 5. Wall Sleeve Unit Dimensions Unit Dimensions PTAC-SVX01C-EN...
  • Page 9: Air Discharge

    Top of wall sleeve 5.00” 12.62 Bottom of wall sleeve Toe plate 0 to 3.0” long Figure 8. Hydronic kit side view PTAC-SVX01C-EN Unit Dimensions PTAC Wall Sleeve Steam inlet and outlet connection Steam/water (right hand coil connection) coil position 53-2/3”...
  • Page 10: Installation

    The power cord measures 60 inches, with 56 inches usable from the point where the cord exits the unit cabinet and the attached plug. PTAC-SVX01C-EN...
  • Page 11 Rating Unit plug Plug amp rating NEMA 6-15P 6-20P 6-30P designation Receptacle Receptacle amp rating NEMA 6-20R 6-20R 6-30R designation PTAC-SVX01C-EN Installation Building circuit requirement Unit Btu/h at Total total Minimum (iii) 265V watts amps ampacity 2000/ 8.9/7.9 1600 3000/ 13.4/11.8...
  • Page 12: Installation Procedure

    For variable frequency drives or other energy storing components provided by Trane or others, refer to the appropriate manufacturer’s literature for allowable waiting periods for discharge of capacitors. Verify with an appropriate voltmeter that all capacitors have discharged.
  • Page 13 Note: For installation procedures, please refer to the Installation Guide that accompanied the accessory. PTAC-SVX01C-EN Installation Step 4. Install wall sleeve in wall opening. For condensate to drain properly inside the unit, the sleeve must be installed properly: •...
  • Page 14 Universal Power Cord 15 Option 1. A field supplied 115 volt 15 amp receptacle is mounted in the building floor or wall. A Trane 115 volt 15 amp power cord BAYPCRD007 is connected to the PTAC and plugged into the receptacle.
  • Page 15 High Emgcy Heat Low Emgcy Heat PTHE Heat Pump Auxiliary is Electric only High Cooling Low Cooling High Fan Low Fan PTAC-SVX01C-EN Installation Table 7. Wiring Voltage Unit Mode High Heat Pump High Auxiliary Heat Low Auxiliary Heat PTEE Air Conditioner...
  • Page 16 The PTAC subcools the room to a preset state, a dehumidification offset below the cooling setpoint. The unit will automatically adjust the fan speed. When incorporating the vent door option, the controller will automatically adjust its position. PTAC-SVX01C-EN...
  • Page 17 In order for the user to access the configurable parameters, a digital display module must be present. The configuration set-up mode is entered by pressing and holding the "MODE" and "FAN" buttons simultaneously for 5 seconds. PTAC-SVX01C-EN Installation Table 9. Set point configuration Configuration Configuration step...
  • Page 18 IP (English) 77 (DEFAULT) SI (Metric) 24.5 Table 11. Setpoint limiting Cooling Setpoint Heating Setpoint Selection High Low Limit Limit Limit 50°F 90°F 50°F 55°F 90°F 50°F 60°F 90°F 50°F 65°F 90°F 50°F High Limit 90°F (DEFAULT) 85°F 80°F 75°F PTAC-SVX01C-EN...
  • Page 19: Energy Management System

    When the controller is in the occupied state, the unit runs space comfort control using the occupied setpoints. All heating/cooling/ ventilation features are enabled. PTAC-SVX01C-EN Installation Occupied Standby state When the controller is in occupied standby state, the unit runs space comfort control using the occupied standby setpoints.
  • Page 20 60 sec N/A (Off) 20 sec Reversing Ventilation Time in Valve Heat Door/Fan Step 10 sec 20 sec 20 sec 20 sec 20 sec 20 sec OffOn 60 sec OffOn 60 sec OnOff 60 sec OnOff 60 sec 20 sec PTAC-SVX01C-EN...
  • Page 21: Operation

    Sensor The PTAC can accommodate a field- installed door switch and occupancy sensor to operate the energy management feature. PTAC-SVX01C-EN Operation Remote Thermostat Control Each unit can be operated from any standard 4 or 5-wire, remote- mounted thermostat. Also, the unit...
  • Page 22 See Figure 31. Rotate the grille 180° end-for- end. Reinstall the screws securing the discharge air grille to the cabinet front. Reinstall the cabinet front on the unit. Screws Figure 18. Discharge air grille PTAC-SVX01C-EN...
  • Page 23 Heating amps 208V 11.8 230V 13.4 265V 11.6 Certified in accordance with the Unitary Air-Conditioner Equipment Certification Program, which is based on ARI Standard 310/380. Notes: PTAC-SVX01C-EN Operation PTEE 09 8,800 9,000 8,700 12,000 11,600 11,800 11,800 11.5 11.4 11.4 11.3...
  • Page 24 19.3 11.6 PTHE 15 13,600 11.0 12,500 1230 1260 1260 13,700 5,500 8,200 13,700 10,200 17,100 10,200 17,100 4,000 1,600 2,400 4,000 5,000 2,000 3,000 5,000 5,000 2,000 3,000 5,000 19.7 11.8 19.7 22.2 13.4 22.2 19.3 11.6 19.3 PTAC-SVX01C-EN...
  • Page 25 PTHE0702 PTHE0901 Temperature across Room indoor coil (∆ T) airdry Room air wet bulb bulb rating Btu/H 7300 7600 rating cfm PTAC-SVX01C-EN Operation PTEE0901 PTEE0902 PTEE1201 Temperature across Temperature across indoor coil (∆ T) indoor coil (∆ T) 8800 9000 11700...
  • Page 26 Shaded area is rating ampere Notes: Operation PTHE0902 PTHE1201 PTHE1202 PTHE1501 PTHE1502 Temperature Temperature across acrossndoor coil (∆ T) indoor coil (∆ T) PTEE0901 PTEE0902 PTEE1201 PTHE0901 PTHE0902 PTHE1201 Temperature across indoor coil (∆ T) PTEE1202 PTEE1501 PTEE1502 PTHE1202 PTHE1501 PTHE1502 PTAC-SVX01C-EN...
  • Page 27 Rating 6200 6400 6400 Point 5900 6100 6100 5600 5800 5800 5300 5500 5500 5000 5200 5200 4800 5000 5000 PTAC-SVX01C-EN Operation PTHE PTHE PTHE PTHE PTHE PTHE 0901 0902 1201 1202 1501 1502 1210 1235 1030 1115 1295 1435...
  • Page 28 UNIVERSAL POWER CORD 265 VOLT - 30 AMP Display Module DISPLAY MODULE (AMERICAN STANDARD LOGO STANDARD) DISPLAY MODULE (AMERICAN STANDARD LOGO & DEHUMIDIFICATION) DISPLAY MODULE (TRANE LOGO STANDARD) DISPLAY MODULE (TRANE LOGO & DEHUMIDIFICATION) Escutcheon Cover ESCUTCHEON COVER FOR FRONT PANEL (AMSTD LOGO)
  • Page 29 Extended standard base kick plate 7" to 13" Upgraded kick plate standard height 2" to 6" (Like the unit ventilator design) Upgraded kick plate extended height 7" to 13" (Like the unit ventilator design) Color Standard Soft Dove II Special Color PTAC-SVX01C-EN Operation...
  • Page 30: Maintenance

    Refer to Figure 21. The filter can be cleaned by running under a low pressure hose or sink faucet. PTAC-SVX01C-EN...
  • Page 31: Refrigeration System Service

    It is advisable to remove the unit from the sleeve and thoroughly clean the basepan and condenser coil on a periodic basis. PTAC-SVX01C-EN Maintenance • If the unit is installed ocean side or in a corrosive atmosphere, its life may be greatly reduced by the corrosive environment.
  • Page 32: Brazing

    1400°F . • SILVER SOLDER (Alloy of 30% silver, 38% copper, 32% zinc): use with fluoride base flux on copper to steel, brass to copper, steel to steel, or brass to steel. Recommended heat is approximately 1200°F . PTAC-SVX01C-EN...
  • Page 33: Evacuation

    Figure 22. Refrigeration sealed system — heat pump (air conditioning model Figure 23. Refrigeration sealed system — Heat pump (heat pump model) PTAC-SVX01C-EN Maintenance Evacuation CAUTION Fan Motor Overheat! Never test operation without the unit in the wall sleeve. A serious...
  • Page 34 Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Place discharge and inlet air thermostats Place inlet thermostat in center of grille Figure 24. Proper placement of discharge and inlet air thermostats PTAC-SVX01C-EN...
  • Page 35: Cooling Performance Test

    For best results, perform the test under peak load conditions. The air conditioner must operate at least 20 minutes on the HIGH COOL position before testing. PTAC-SVX01C-EN Maintenance Cooling Performance Test Record the following temperatures for the cooling performance test: •...
  • Page 36 Doing so could result in death, serious injury, or property damage. If the test indicates shorted, grounded or open windings, see procedure for the next steps to be taken. PTAC-SVX01C-EN...
  • Page 37: Ground Test

    Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PTAC-SVX01C-EN Maintenance With no power and compressor leads removed: Set an ohmmeter on its highest scale.
  • Page 38: Table 27. Thermistor Indoor Coil Resistance

    1.1785 1.2158 1.2540 82.0 1.1409 1.1773 1.2148 83.0 1.1047 1.1403 1.1770 84.0 1.0698 1.1047 1.1405 85.0 1.0362 1.0703 1.1054 86.0 1.0038 1.0372 1.0715 87.0 0.9726 1.0052 1.0388 88.0 0.9425 0.9744 1.0073 89.0 0.9135 0.9447 0.9769 90.0 0.8858 0.9161 0.9476 PTAC-SVX01C-EN...
  • Page 39 The serviceman must be familiar with the operational characteristics of the product and should not jump to conclusions. PTAC-SVX01C-EN Maintenance Temperature-Actuated Drain Valve (model PTHE Only) The PTHE is equipped with a temperature-actuated drain valve located in the base pan.
  • Page 40 Reinstall the sheet metal cover over the control board. Position the front cabinet over the chassis and push the sides until the retaining clips engage. Figure 28. Power jumper PTAC-SVX01C-EN...
  • Page 41: Diagnostics

    The last step of the sequence resets the controller. See the Manual output test section on page 22 for more information about the manual output test. PTAC-SVX01C-EN Troubleshooting Cycling Power When someone turns off the controller’s power, then re-applies power, the unit cycles through a power up sequence.
  • Page 42 During the active defrost cycle the outdoor fan is controlled off. See the section on defrost control. Unit wiring The wiring between the controller outputs and the fan relays and contacts must be present and correct for normal fan operation. Troubleshooting PTAC-SVX01C-EN...
  • Page 43 The wiring between the controller output and the ventilation must be present and correct for normal operation. Normal operation See the section on Ventilation operation. Defrost Cycle During the active defrost cycle the outdoor fan is controlled off. See the section on defrost control. PTAC-SVX01C-EN Troubleshooting...
  • Page 44 The indoor fan continues to run after the compressor or auxiliary heat will be on. Table 39. Control fuse is blown Symptom The generic thermostat does not work The energy input does not work The ventilation input does not work The remote fan output does not work Troubleshooting PTAC-SVX01C-EN...
  • Page 45: Wiring Diagram

    3) For different electric heater capacity, refer to IOM for power cord selection. 4) The specs for the control board fuse are: 5 x 20mm, 250V, 315mA, fast acting. Figure 29. 230/208V wiring diagram (07 models) PTAC-SVX01C-EN Wiring Diagram K8 HEAT K9 COOL Rev Valve...
  • Page 46 8 7 6 5 4 3 2 1 YL/GR 1.0KW 2.0KW 2.0KW RD - RED GR - GREEN WH - WHITE BK - BLACK OR - ORANGE YL - YELLOW FACTORY WIRING BL - BLUE FIELD WIRING BR - BROWN PTAC-SVX01C-EN...
  • Page 47 3) For different electric heater capacity, refer to IOM for power cord selection. 4) The specs for the control board fuse are: 5 x 20mm, 250V, 315mA, fast acting. Figure 31. 265V Wiring diagram (07 models) PTAC-SVX01C-EN Wiring Diagram K8 HEAT K9 COOL Rev Valve...
  • Page 48 8 7 6 5 4 3 2 1 YL/GR RD - RED GR - GREEN WH - WHITE INDOOR MOTOR BK - BLACK OR - ORANGE YL - YELLOW FACTORY WIRING BL - BLUE FIELD WIRING BR - BROWN PTAC-SVX01C-EN 1.0KW 2.0KW 2.0KW...
  • Page 49 R W Y GH GL O VT EN Figure 33. Energy management system R W Y GH GL O VT EN Figure 34. 3rd party class 2 thermostat wiring Figure 35. Remote display wiring PTAC-SVX01C-EN Wiring Diagram...
  • Page 50: Warranty

    Warranty Full 1st Year Warranty Trane will repair or replace any part which proves to be defective due to workmanship or materials, free of charge. This includes parts and labor. Full 2nd - 5th Sealed System Warranty Trane will repair or replace the...
  • Page 52 Literature Order Number PTAC-SVX01C-EN Date 09/06 Supersedes PTAC-SVX01B-EN Stocking Location Webb/Mason The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.