The °C display (LED 5) indicates the gas temperature in °C.
Switch output 1
•
Switch signal as the limit value for volume flow, hysteresis or
window function as NO or NC contact.
•
Pulse sequence for adjustable consumption quantity, e.g.
1 pulse/m³ (pulse length 100 ms) or quantity monitoring via pre-
set counter ( Setting the preset counter / pulse value (ImPS),
page 36).
Switch output 2
•
Switch signal as the limit value for volume flow, hysteresis or
window function as NO or NC contact.
•
Analogue signal (4 to 20 mA) for corresponding volume flow.
Sensor type
Sensor up to 80 m/s
Sensor up to 160 m/s 0.33 % – 100 %
Nominal width Measuring range
DN 40
DN 50
DN 65
DN 80
DN 100
DN 125
DN 150
DN 200
DN 250
2
Absolute measuring range depends on the nominal width (see following table)
3
Specifications acc. to DIN ISO 2533 (15 °C, 1013 hPa and 0 % rel. humidity).
Initial measuring range is different to display resolution
Measuring range
0.33 % – 50 %
3
(80 m/s)
0.03 – 5.2 m³/min
0.06 – 8.3 m³/min
0.11 – 16.7 m³/min
0.15 – 22.9 m³/min
0.24 – 36.7 m³/min
0.39 – 58.3 m³/min
0.55 – 83.3 m³/min
0.9(7) – 145.8 m³/min
1.5(3) – 229.2 m³/min
Based on the small size, the sensor only has a small
contact surface. The pressure loss is thus negligible
(typically 1 mbar).
2
Recording/display range
0 % – 60 %
0 % – 120 %
Measuring range* (160 m/s)
0.03 – 10.4 m³/min
0.06 – 16.7 m³/min
0.11 – 33.3 m³/min
0.15 – 45.8 m³/min
0.24 – 73.3 m³/min
0.39 – 116.7 m³/min
0.55 – 166.7 m³/min
0.9(7) – 291.7 m³/min
1.5(3) – 458.3 m³/min
4 Product description