Gabarron Elnur INGENIUM Series Installation Instructions & User Manual page 8

Wifi thermal radiators
Table of Contents

Advertisement

0:00
3.9. Keyboard Lock
Note: To activate the adaptive start control please refer to C6 in 3.10. ADVANCED CONFIGURATION section.
In every operation mode, it is possible to lock the keyboard by holding "+" and "-" buttons simultaneously for
3 seconds. When the keyboard is locked, the message Lock will be displayed.
When the keyboard is locked, if any button is pressed, the display will show "Lock" and the unit will not respond.
3.9. KEYBOARD LOCK
In every operation mode, it is possible to lock the keyboard by holding "+" and "-" buttons
simultaneously for 3 seconds. When the keyboard is locked, the message Lock will be displayed.
21.0C
Loc K
When the keyboard is locked, if any button is pressed, the display will show "Lock" and the unit will
AUTO
not respond.
To unlock the keyboard, press the "+" and "-" buttons simultaneously for 3 seconds.
To unlock the keyboard, press the "+" and "-" buttons simultaneously for 3 seconds.
0:00
3.10. Advanced Configuration
3.10. ADVANCED CONFIGURATION
3.10.1 To access to advanced configuration menu, Press
3.10.1 To access to advanced configuration menu,
& Release Config/Prog button until the following is
displayed:
Press & Release Config/Prog button until the
following is displayed:
21.0C
AUTO
Use the same procedure to modify the others parameters where necessary. It is possible to exit of advanced
Use the same procedure to modify the others parameters where necessary. It is possible to exit of advanced configuration by
configuration by pressing the Config/Prog button at any time.
pressing the Config/Prog button at any time.
Parameters
- C1. Fahrenheit or Celsius Degrees.
The LCD displays the temperature unit selected: ºC or ºF.
- C2. Control Adjustment.
The kind of temperature control can be modified with this parameter:
PID, Hysteresis 0,25ºC, Hysteresis 0,35ºC, Hysteresis 0,50ºC, Hysteresis 0,75ºC.
- C3. Correction of ambient temperature measures.
If there is a difference between an external thermometer and the temperature displayed by the unit, with C3
parameter it is possible to influence on the sensor in order to balance the difference. (-3ºC to +3ºC in 0,1 steps).
- C4. Firmware version.
Information about the current firmware version of the unit.
- C5. Open Window Activation
ON/OFF. With the parameter in ON, the open window detection is activated.
- C6. Adaptive Start Control
ON/OFF. With the parameter in ON, the adaptive start control is activated.
Elnur powered by Gabarrón | INGENIUM WIFI Thermal Radiators | Installation Guide
Pro
AUTO
0:00
3.10.2 Hold the Config/Prog button for 5 seconds, the
first parameter (C1) will be displayed. To select the next
3.10.2 Hold the Config/Prog button for 5 seconds, the first parameter
parameter, press the "+" button.
(C1) will be displayed. To select the next parameter, press the "+"
button.
21.0C
Pro
AUTO
AUTO
6
To modify the value of the
parameters, press the OK/
To modify the value of the parameters,
Mode button. Then use the
C 1
press the OK/Mode button. Then use the
"+" and "-" buttons to select
the different options. Press
"+" and "-" buttons to select the different
the Ok/Mode button again
options. Press the Ok/Mode button again
to set the value.
to set the value.
Pro
AUTO
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents