Class I, RInsu-2, sec. - PE, with BENNING MA 2-16
Switch position of measuring adapter: any
Connection diagram
VDE 0701-0702, VDE 0751-1, VDE 0544-4
Circuit diagram
VDE 0701-0702, VDE 0751-1, VDE 0544-4
(switch position IPE direct or IPE Δ)
Connect the BENNING MA 2-16 measuring adapter to the
BENNING ST 755/ ST 760 appliance tester according to the
connection conditions.
The switch position of the orange toggle switch on the surface of
the BENNING MA 2-16 is arbitrary.
Start the RInsu-2 measurement at the appliance tester (automatic
test or manual test).
Use the test probe to scan the bridged poles of the secondary
output voltage and follow the instructions shown on the display of
the appliance tester.
Class I, RInsu-3, LN - sec., with BENNING MA 2-16
Switch position of measuring adapter: any
Connection diagram
VDE 0701-0702, VDE 0751-1, VDE 0544-4
Circuit diagram
VDE 0701-0702, VDE 0751-1, VDE 0544-4
(switch position IPE direct or IPE Δ)
Connect the BENNING MA 2-16 measuring adapter to the
BENNING ST 755/ ST 760 appliance tester according to the
connection conditions.
The switch position of the orange toggle switch on the surface of
the BENNING MA 2-16 is arbitrary.
Start the RInsu-3 measurement at the appliance tester (automatic
test or manual test).
Use the test probe to scan the bridged poles of the secondary
output voltage and follow the instructions shown on the display of
the appliance tester.
65