DIF Messages
ALTERNATE TRACK ASSIGNMENT MAP FULl. CHANGE DISK
Cause:
Maximum number of alternate tracks reached.
Action: Change the disk.
ERROR ON TRACK
o.
CHANGE DISK
Cause: An error has been detected on track
o.
Action: Change the disk.
ERROR WHILE FLAGGING BAD TRACK. CHANGE DISK
Cause:
It IS not possible to flag a bad track.
Action: Change the disk.
FORMAT COMMAND FAILED. CHANGE DISK
Cause: A disk error has been detected dUring disk format.
Action: Change the disk.
INCREASING IN DISK SIZE - PLEASE WAIT SEVERAL MINUTES
DIF Messages
Cause: A 72MB disk (phYSical capability) was formatted to 45MB only. The system IS formatting the remaining part to allow
usmg the entire disk capacity.
Action:
No operator action. The operation IS automatically performed.
HARDWARE CONFIGURATION SUPPORTS UP TO 4MB NCP LOAD MODULE
Cause: The disk IS a 45MB disk and therefore cannot support an NCP load module greater than 4MB.
Action:
Depending on the user's needs:
• The user does not want to use a 6MB NCP load module: no action.
• The user wants to use a 6M B NCP load module: exchange the disk for a 72M B disk.
Note: 6MB NCP load module IS available starting from microcode EC A47035 level.
HARD DISK FAILURE; CHANGE YOUR DISK TO SUPPORT 6MB LOAD MODULE
Cause: The disk IS a 72MB disk (phYSical capacity) and was formatted up to 45MB only. An error occured while formatting
above 45M B. Therefore that disk cannot support an NCP load module greater than 4M B.
Action:
Dependmg on the user's needs:
• The user does not want to use a 6M B NCP load module: no action.
• The user wants to use a 6MB NCP load module: exchange the disk for a 72MB disk.
Note: 6M B NCP load module IS available starting from microcode EC A47035 level.
NO DEFECTIVE TRACK: ALTERNATE TRACK ASSIGNMENT MAP EMPTY
Cause:
No defective track detected dUring initialization of the hard disk.
Action:
None
Refer to the 3745 Advanced Operations Guide, SA33-0097, for an explanation of the following messages
which are common to the customer and the CE:
• CCU FUNCTIONS NOT ALLOWED
• CCU/MOSS ERROR: DISK FUNCTIONS CAN NOT BE PERFORMED. PRESS SEND
• DISK DIRECTORY CAPACITY EXCEEDED: MOSS DOWN
• DISK ERROR: FUNCTION CANCELED. PRESS SEND
• DISK ERROR: MOSS DOWN
• DISK ERROR: SAVE CANCELED
• DISK FUNCTIONS CAN NOT BE PERFORMED WHEN MOSS IS ONLINE
• DISK NOT INITIALIZED
• DISK UNUSABLE. EC NOT INITIALIZED
• DISKETTE ERROR: FUNCTION CANCELED. PRESS SEND
• DISKETTE ERROR: MOSS DOWN
• DISKETTE ERROR. MOUNT A NEW ONE. THEN PRESS SEND
• DISKETTE NOT READY
• EC INSTALLATION FROM FIFTH DISKETTE IN PROGRESS
• EC INSTALLATION FROM FOURTH DISKETTE IN PROGRESS
• EC INSTALLATION FROM PRIMARY DISKETTE IN PROGRESS