IBM 3745 Series Service Functions page 34

Communication controller
Table of Contents

Advertisement

MSA (Token-Ring/TIC Information)
MSA Field Definitions (Token-Ring/TIC Information)
Field W
Field X
CUSTOI·IER 10:
3745-x10
SERIAL
~IUI·IBER:
CCU-A SELECTED PROCESS MOSS OFFLINE
RUN
STOP-IOC-CHK STOP-CCU-CHK
TRA 1
DISCOtINECT
TIC 1
OPEN
NCP TRS NOT AVAILABLE
------------------------------------------------------------- mm/dd/yy
10:20
FUNCTION ON SCREEN: TRSS SERVICES
FUNCTION PENDING:
Figure
1-15. MSA Example with TRSS Information
Token-ring information is displayed on line 4 for CCU-A, and on line 7 for
CCU-B.
CUSTOMER ID:
3745
SERIAL NUI·IBER:
CCU-A SELECTED PROCESS MOSS OFFLINE
RUN
STOP·IOC-CHK STOP-CCU-CHK
B
/oISCONNECT
B
I
OPEN
NCP TRS NOT AVAILABliJ
& &
& &
~
Figure
1-16. Fields of the TRSS Information in the MSA
This figure shows the breakdown of the token-ring information fields in line 4
(CCU A) or 7 (CCU B).
TRA number (1, 2, 5 or 6). Indicates that the TRA has been selected (TRS or
TID function).
TRA mode, updated after TRA selection (option
1
in the TRSS function selection
screen, page 5-5).
Note: If field F indicates CCU INTERRUPTS DISABLED, the TRA mode has no
meaning.
The possible modes are:
CONNECT:
The TRA is operational and is under NCP control. The control
program handles all interrupts (except if there is an MIOH
error).
The PIO disable and the disconnect bits in the TRM level 1
error status are OFF.
DISCONNECT:
The TRA does not run under the control of the control program
but under the control of the MOSS microcode. MOSS handles
all interrupts and PIOs to/from the TIC.
The PIC disable and the disconnect bits in the TRM level 1
error status are OFF.