CDF Messages
DISCREPANCY BETWEEN OPERATOR AND SENSED MUX NUMBER
Cause:
The MUX number chosen by the operator does not match the MUX number detected dUring hardware sensing.
Action: Check and enter the correct MUX number.
DISCREPANCY BETWEEN OPERATOR AND SENSED EXTEND VALUE
Cause:
The operator has chosen the 'NO EXTEND' option, and the EXTEND has not been sensed (or vice-versa).
Action:
Check and enter the correct option.
DISCREPANCY BETWEEN CDF AND SENSED TPS VALUE
Cause:
The CDF TPS value does not match the TPS value sensed dUring a hardware change.
Action:
Run an upgrade.
DISCREPANCY BETWEEN OPERATOR AND SENSED TPS VALUE
Cause:
The operator has chosen the 'TPS' option, and the TPS has not been sensed (or vice-versa).
Action:
Check and enter the correct option.
ERROR IN AMAC, TCM/PUC, OR CABLES. CONTACT SERVICE REPRESENTATIVE
Cause: CCU type cannot be sensed on CCU-A.
Action:
Refer to the Mamtenance Information Procedures for details.
ERROR WHILE SENDING MAILBOX TO NCP : ACK
= )()()()(
CC
=
xx
Cause: Wrong data has been sent or wrongly processed by the NCP.
The ACK field can be:
• 8000: In mailbox accepted
• 4004: Fallback In progress
• 4008: Invalid parameter
• 4020: Invalid command
• 4040: Function not supported
When the In mailbox IS accepted but the NCP return code (completion code CC = xx) IS not recognized by the CDF, this error
message IS displayed with the CC value.
Action: Call the PE for the investigation.
ESC RANGE MUST BE BLANK IN TPS MODE
Cause:
The operator has entered a wrong ESC range.
Action:
Keep the ESC range blank.
EXTEND NOT ACCEPTED
Cause:
The next MUX IS already attached.
Action:
Select the correct option without EXTEN D.
EXTEND PRESENCE MANDATORY, SELECT Y OR N
Cause:
The operator did not enter Y or N.
Action:
Retry with the correct Input (Y or N).
FUNCTION ALREADY PERFORMED
Cause:
DUring a hardware change, the same function was already performed.
Action:
None.
INSTALL MODE NOT ESTABLISHED
Cause:
DUring a CA hardware change, that CA IS attached, not Installed, and Install IS not
In
progress. The sequence of com-
mands was invalid.
Action:
Restart a valid sequence of commands.
INVALID EXTEND PRESENCE, ENTER Y OR N
Cause:
DUring an LA hardware change, the operator did not enter Y (yes) or N (no).
Action:
Enter Y or N.
INVALID MUX NUMBER, ENTER 1 TO 32
Cause:
The operator has entered a MUX number which IS not
In
the range from 1 to 32.
Action:
Retry with a correct value.
INVALID PORT RANGE
Cause: The operator has entered a port range which IS not
In
the range from 0 to 1095.
Action:
Retry with a correct value.
Chapter 9. Configuration Data File (CDF)