Panasonic FP Series Programming Manual page 247

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

Conversion instructions
UINT_TO_BCD_WORD
UINT_TO_BCD_WORD converts a value of the data type Unsigned INTEGER into a BCD value of
Description
the data type WORD.
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
Availability of UINT_TO_BCD_WORD (see page 1332)
PLC types
Data types
Data type
UINT
BCD_WORD
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
POU header
All input and output variables used for programming this function have been declared in the POU
header.
LD
ST
BCD_value_16bit:=UINT_TO_BCD_WORD(UINT_value);
246
Unsigned INTEGER into BCD value of WORD
I/O
Function
Input
input data type
Output
conversion result

Advertisement

Table of Contents
loading

Table of Contents