5.3 Default settings

In order to restore the default settings EPC NET 24x must be
started in bootloader mode (see 5.1). Besides that the program
GBL_Conf.exe is required.
Run GBL_Conf.exe and select the EPC NET 24x whose set-
tings should be restored. Then click on Program Device
to Fab default.
Please notice that all current settings will be deleted. The default
settings will be loaded when EPC NET 24x is restarted the next
time.
Factory Settings EPC NET 24x
Name:
IP adress:
Netmask:
Gateway:
DHCP:
Password
HTTP Port:
IP ACL:
Power Port 1-24
Name:
After Reboot:
EPC-NET-24x
192.168.0.2
255.255.255.0
192.168.0.0
enabled
disabled
80
disabled
Power Port 1 - 24
disabled
Expert Power Control NET 24x
Reset
g