Expert Power Control 1000 / 1001 Safety Advice Safety Advice The device must be installed only by qualified personnel according to the following installation and operating instructions. The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equipment that may cause personal injury or material damage.
5) Button Installation 1.) Connect the power supply cable to the of Expert Power Control 1000 / 1001 and a socket. Expert Power Control 1000 / 1001 now is booting and shortly after ready for usage. 2.) Plug the Ethernet cable into the ethernet connector (RJ45) of Expert Power Control 1000 / 1001 and connect it to your Ethernet.
Enter a free IP address and the according netmask in the entry mask, then save these changes by clicking on Program Device SaveConfig. Restart the firmware of Expert Power Control 1000 / 1001, so that the changes will take effect. Now click on Search in order to have the new network configuration displayed.
Configuration Configuration via webinterface Go to the website of Expert Power Control 1000 / 1001. Enter the IP address of Expert Power Control 1000 / 1001 into the address line of your internet browser: http://”IP address of Expert Power Control 1000 / 1001”/ and press LOGIN.
Configuration - IP address 4.3.2.1 Hostname Enter the host name of Expert Power Control 1000 / 1001. Expert Power Control 1000 / 1001 uses this name to connect with DHCP server. Special signs may destabilize your network. All changes need a restart of the firmware to get valid.
Configuration - IP ACL IP Access Control List (IP ACL) acts as an IP filter for your Expert Power Control 1000 / 1001. Wether it is active hosts and subnets only can contact Expert Power Control 1000 / 1001, if their IP adresses are stated in this IP ACL.
Password protected access can be activated here. In this case, a user and an admin password have to be defined. Passwords have a maximum lengths of 15 characters. Administrators are authorized to switch all ports and to modify the settings of Expert Power Control 1000 / 1001 and of all ports. The username of the admin is “admin”.
Page 11
All information, that can be requested or changed, the so called „Managed Objects“, are descripted in „Management Information Bases“ (MIBs). There are three MIBs, which can be requested from Expert Power Control 1000 / 1001: „system“, „interface“ and „powerports“ „system“ and „interface“ are standardised MIBs (MIB-II).
Here you can choose between SNMP-traps standard v1 and v2c. Use SNMP only if your network is fitted for. More information about the SNMP functions of Expert Power Control 1000 / 1001, you can find in chapter SNMP, on http:// www.gude.info/wiki or ask our support team.
Switching at the device On the front of Expert Power Control 1000 / 1001 a button is located. When the device is running, you can change the Power Port status by pushing this button. The LED on the upper side of fthe device indicates the recent switching status...
Operation Switching by Webinterface Go to the website of Expert Power Control 1000 / 1001. Enter the IP address of Expert Power Control 1000 / 1001 into the address line of your internet browser: http://”IP address of Expert Power Control 1000 / 1001”/ and press LOGIN 5.2.1...
Bootloader mode To activate the bootloader mode of Expert Power Control 1000 / 1001 the button must be pushed while restarting the device. In bootloader mode it is possible to disable the password protection, to update the firmware and to restore the default settings by running the program GBL_Conf.exe.
Expert Power Control 1000 / 1001 Support Support In case of further questions, about installation or operation of the device, please have look at www.gude.info/wiki or do not hesitate to contact our support (mail@gude.info).