Specifications

Item
Optical system
Microscope frame
Illumination system
Power consumption
Focusing mechanism Stage height adjustment mechanism
Tube
Eyepiece
Revolving nosepiece 5-hole revolving nosepiece is fixed. (Up to five objectives with outer diameter of Ø24 only can be attached.)
Stage
Condenser
Dimension
Weight
Operating
environment
Transportation/storage
environments
34
Infinity optical system
CX43RF / CX43LF
Built-in LED light source
Microscope frame (rated input power): 5 V 0.85 A
AC adapter (rated input power): 100-240V
AC adapter (rated output power): 5V
2.4W
Movement distance per scale of fine focusing knob: 2.5µm
Movement distance per rotation of fine focusing knob: 0.3mm
Movable range: 15mm
Equipped with pre-focusing lever; Tension adjustable coarse focusing knob
U-CTR30-2 Trinocular tube
(Eyepiece 50%, Camera 50%)
Model type
U-CBI30-2
Binocular tube
U-CTBI
Tilting binocular tube
Intermediate attachment See page 18.
WHB10X
WHB10X-H (with diopter adjustment)
Movable range
X direction: 76mm
Y direction: 52mm
Specimen holder
Possible to hold 2 slide glasses Possible to hold 1 slide glass
Option
CX3-SHP
(Specimen hold plate)
Model type
Abbe condenser
Numerical aperture
1.25 (when immersed with oil)
Aperture diaphragm
Illumination aperture diaphragm blade, manual open/close type
Turret selection type (BF, DF, FL, Ph1, Ph2, Ph3, 2X)
CX43RF / CX43LF only: 211 (W) x 297 (D) x 291 (H) mm
CX43RF / CX43LF with trinocular tube and eyepieces:
211 (W) x 373 (D) x 393 (H) mm (when the interpupillary distance is 62 mm)
CX43RF / CX43LF only: Approx. 5.9 kg
CX43RF / CX43LF with trinocular tube and three objectives: Approx. 7.3 kg
(Both of them are not including AC adapter)
· Indoor use
· Altitude: Max. 2000 meters
· Ambient temperature: 5 to 40 °C (41 to 104 °F)
· Humidity: Max. 80% (31 °C or less) (without condensation)
In case of over 31 °C (88 °F), the humidity in operating environment is decreased linearly
through 70% at 34 °C (93 °F), 60% at 37 °C (99 °F), and to 50% at 40 °C (104 °F).
· Supply voltage fluctuation: ±10 %
· Pollution degree: 2 (in accordance with IEC60664-1)
· Installation (overvoltage) category: II (in accordance with IEC60664-1)
· Ambient temperature: -25 to 65 °C (41 to 104 °F)
· Humidity: 0% to 90% (without condensation)
Specification
50-60 Hz 0.4A
2.5A
Field number: 20
Tube tilting angle: 30°
Field number: 18 (fixed eyepieces)
Tube tilting angle: 30° to 60°
Field number: 20
CX43LF
CX3-SHP (Specimen hold plate)
CX3-HLDT (Specimen holder)
CX43RF