Verify The Replacement Component; Install The Psu; Switch Port Layout - Dell EMC DP5300 Field Replacement Manual

Integrated data protection appliance (idpa)
Table of Contents

Advertisement

DELL EMC CONFIDENTIAL
Dell S4048-ON Switch FRUs

Verify the replacement component

1
3
5
7
9
2
4
6
8
10
Integrated Data Protection Appliance (IDPA) 2.1 Field Replacement Guide
70
Figure 17 Install the PSU
1. PSU
2. PSU slot
7. Plug the power cord into the connector on the power supply unit.
The PSU powers up as soon as the cable is connected.
8. Indicate that the PSU is operating normally by checking the LEDs on the PSU
and the front panel.
9. Using the shipping materials that the replacement PSU shipped in, re-package
the faulted PSU and prepare the package for return shipping.
Verifying the component replacement requires connecting to the Dell switch to access
the Dell switch management interface. Connect to port 38 on the Dell switch. The
switch port layout is displayed in the following table.
Table 17 Switch port layout
11
13
15
17
19
21
12
14
16
18
20
22
Procedure
1. Log in to the Dell switch with the username admin, and the customer-provided
password.
2. Verify the status of the replacement component is up.
Run the following command: