Prepare A Failed Ssd For Replacement - Dell EMC DP5300 Field Replacement Manual

Integrated data protection appliance (idpa)
Table of Contents

Advertisement

DELL EMC CONFIDENTIAL
Dell PowerEdge R630 Server FRUs

Prepare a failed SSD for replacement

Integrated Data Protection Appliance (IDPA) 2.1 Field Replacement Guide
34
8. Select DPappliance-VSAN cluster.
9. Select Manage
Settings
>
10. Locate and expand the ESX host with the failed drive, and record the disk group
with Unhealthy status.
11. Select the unhealthy disk group, and select the drive with Failed or Error status.
12. Select All Actions
13. Open a new browser window, and type in the iDRAC IP address to access the
server iDRAC interface.
14. Accept any SSL certificate errors.
15. Log in as root with the customer-provided password.
16. Select Storage
Physical disks, and record the slot number of the failed disk.
>
After you finish
Do not disconnect the service computer from the network switch, and do not
terminate the iDRAC or vCenter Server sessions. Additional steps are required to
configure the replacement disk.
This task only applies to replacing a failed SSD. Skip this section when replacing an
HDD. To prepare the SSD for replacement, complete the following steps.
Virtual SAN
>
>
Turn Locator LED on.
>
Disk Management.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp5800Dp8300Dp8800

Table of Contents